Generac Portable Products 9777-3 Owner's Manual page 10

4000 watt extended life generator
Table of Contents

Advertisement

120/240 Volt AC, 20 Amp
Locking
Receptacle
Use a NEMA LI4-20 plug with this receptacle. Connect a
4-wire cord set rated for 250Volts at 20 Amps (or greater)
(Figure I I).You can use the same 4-wire cord if you plan to
run a 120Volt load.
pa_
Ip,(*]kv_aJr.,T *"
.
*
:"
._ m
4-Wire Cord Set
I
' (Neutral)
Y (Hot)
X (Hot)
NEMA L 14-20
Ground (Green)
This receptacle powers 120/240Volt AC, 60 Hz, single
phase loadsrequiring up to 2,400 watts of power at
20 Amps for 120Volts; 4,000 watts of power (4.0 kW) at
16.7Amps for 240 Volts.The outlet is protected by a
20 Amp push-to-reset circuit breaker.
_L
CAUTION!
Although this outlet is rated for
240 Volt 20 Amp (up to 4,800 watts), the generator
is only rated for 4,000 watts. Powering loads that
exceed the wattage/amperage capacity of the
generator can damage it or cause serious injuries.
240 Volt loads powered through this outlet should
not exceed 16.7Amps of current draw.
120 Volt AC, 30 Amp
Locking
Receptacle
Use a NEMA L5-30 plug with this receptacle. Connect a
3-wire cord set rated for 125Volts AC at 30 Amps to the
plug (Figure 12).
3-Wire Cord Set
i
NEMA
L5-30
Neutral
120V
Hot
Ground (Green)
Use this receptacle to operate 120Volt AC, 60 Hz, single
phase loadsrequiring up to 3,600 watts (3.6 kW) of power
at 30 Amps.The outlet is protected by a 30 Amp
push-to-reset circuit breaker.
12 Volt DC, I 0 Amp
Receptacle
This connector (identified by the legend "I2-VOLT D.C")
supplies 12Volts DC at I 0 Amps through battery charging
cables for recharging 12Volt batteries (Figure 13).See
"Charging a Battery" on page 8.
IIII
Ip,iV_II[IIDI *ql[9]_ll;
_tq