Generac Portable P roducts 3,500 WattGenerator
EQUIPMENT
DESCRIPTION
This generator is an engine-driven, revolving field,
alternating current (AC) generator. It was designed to
supply electrical power for operating compatible electrical
lighting, appliances,tools and motor loads. This manual
contains informationfor a generator that operates 120
and/or 240 Volt, single phase, 60 Hz devices that require up
to 3,500 watts (3.5 kW) of power that pult up to
29.2 Amps at 120 Volts or 14.6Amps at 240 Volts.
_
CAUTION!
Do Not exceed the generator's
wattage/amperage capacity. A dd up the rated watts
of all devices you are connecting to generator
receptacles at one time. This total should not be
greater than 3,500 watts. In most cases rated watts
of the electrical device can be found on the device
nameplate. If the device nameplate gives only volts
and amps, multiply volts times amps to obtain watts
(volts X amps = watts).
The 3,500 watt generator has the following features:
• 120/240 Volt, 20 Amp locking type receptacle and a
120 Volt, 30 Amp locking type receptacle.
• 120 Volt, 15 Amp receptacles.
• Low Oit Shutdown: Automatically shuts down the engine
if oit drops below safe operation level.
• Four gallon overhead fuel tank with fuel gauge.
• The generator's revolving field is driven at about
3,600 rpm by a Generac Power Systems6.5 h.p. engine.
_
ARNING!
Do Not tamper with engine
governed speed. High operating speeds are
dangerous and increase risk of personal injury or
damageto equipment. The generator supplies
correct rated frequency and voltage only when
running at proper governed speed. Incorrect
frequency and/or voltage can damage some
connected electrical loads. Operating at excessively
low speeds imposes a heavy load. When adequate
engine power is not availableengine life may be
shortened.
SAFETY
RULES
This generator set was designed and manufactured for
specific applications. Do Not attempt to modify the unit
or use it for any application it was not designed for. If you
haveany questions about your generator's application, ask
your dealer/distributor or consult the factory.
The manufacturer could not possibly anticipate every
circumstance that might involvea hazard. For that reason
warnings in the manual and warnings on tags or decals
affixed to the unit are not all-inclusive. If you intend to
handle, operate or service the unit by a procedure or
method not specifically recommended by the manufacturer,
first make sure that such a procedure or method will not
render this equipment unsafe or pose a threat to you and
others.
Read this manual
carefully
and become
familiar
with your generator
set. Know its applications,
its
limitations
and any hazards
involved.
_
DANGER!
You must isolate the generator from
the electric utility by opening the electrical system's
main circuit breaker or main switch if this unit is
used for backup power. Failure to isolate the
generator from the power utility may result
in injury or death to electric utility workers
and damage to the generator due to a backfeed
of electrical energy. Whenever unit is providing
backup power, the electric utility must be notified.
_
DANGER!
Generator exhaust gases contain
DEADLY carbon monoxide
gas. Carbon
monoxide, if breathed in sufficient
concentrations, can cause unconsciousness or
death. Operate this equipment outdoors where
adequate ventilation is available.
The Emission Control System for this generator is
warranted for standards set by the Environmental
Protection Agency. For warranty informationrefer to the
engine owner's manual.
/