Performance Data Sheet
SmartWater
Filtration
System
GWF / HWF Cartridge
Thissystemhas been testedaccording to NSF/ANS142/53for reduction of the substanceslisted below.
The concentrationof the indicated substancesin water entering the system was reduced to a concentration
less than or equal to thepermissible limit for water leaving the system,as specified in NSF/ANS142/53.*
(100%safety factors built in for unmetered usage)
Parmneter
Chlorine
T & O
])alqi( ulat( =>
Parameter
USEPA
MCL
USEPA
MCL
Stmldard
No. 42: Aesfllelic
Effects
Influent
Challenge Concentration
2.0 mgiI. + 10%
a* least 10,(100 particlesimI
Standard No. 53: Health Effects
Effluent
Average
Maximmn
0.02 ppm
0.05 ppm
3,978
7,8(;0
]ntluent
Clmllenge
Concentration
ll+INTI***
Minimum
50,000
I
0.17) mg!I.+
10!:i
0.17) ra!!L+
10!:i
0.002
mgiI.
+ 10%
0.001) mgiI.
+ 10%
0.210
mgiI.
+ 10%
10 v to 1(_ _ fiher_/I.;
fiber_ greater
th_nl
10 micvometer_
in length
Effluent
Average
0.07 NT[
26
1 pph
1.8 pph
0.00005 ppm
0.002 ppm
0.042 ppm
0.32 MFI iml
Maxillltlrll
Tu rbidilv
0.1 NTI
Cysts
99.95% Reduction
55
I.ead at pII 6.5
15 pph
l ppb
I.ead at pII 8.5
15 pph
4.3 ppb
IJndane
0.0002 ppm
0.00005 ppm
Atcazine
0.003 ppm
0.0,')3 ppm
2,41)
0.100 ppm
0.090 ppm
,_._l)('stos
99%
1.2 MFLiml
* Testedusinga flow rate of 0.5 gpm;pressureof 60 psig; pHof 7.5_+0.5;temp.of 20°_+2.5°C
** Measurementin Particles/ml.Particlesusedwere 0.5-1 microns
*** NTU=Nephelometric T urbidityunits
% Reduction
Average
_lmn
98.90<7o
t 7.37%
98.00%
t 6.1( %
Min. Required
Reduction
> 50%
> 85!:i
% Reduction
Average
99.71%
99.97%
1)1).37!_i
98.8!:_
91.931:i
76.19%
84.89%
99.95%
Mill. Required
Milfimmn
Reduction
99.59%
0.5 NTI
99.95!1_
> 99.95<7o
00.371:{
0.010 mg!I
97.13!:i
0.010
mg!I
O1.1)3{:i
0.0002 mgiI
64.28%
0.003 mgiI.
67.63%
0.07 mgiL
99.82!:1
99!:1
Operating Specifications
•
Capacity:
certified
fl)r up to 300 galhms
(1135
1); up to six months
fin" models
without
a replacement
filter
indicator
light;
up
to one
vear
for
models
with
a replacement
filter
indicator
light
•
Pressm'e
retluirement:
40-190
psi
(2.8-8.2
bar),
non-shock
•
Temperature:
33-100°F
(0.6-38°C)
•
How
rate:
0.5 gpm
(1.9
lpm)
General Installation/Opera.n/Maintenance
Requirements
•
Flush
new
cartridge
at full
flow foi
3 minutes
to purge
(rot trapped
air.
•
l?,eplace
cartridge
when
flow
becomes
too
slow.
Special Notices
•
Installation
instructions,
parts
and
service
availability,
and
standard
warranty
are
included
with
the
product
when
shipped.
•
This
dlJnking
water
svsteln
illtlSt
be
nlaintained
according
to illalltlfhcttlrer's
instructions,
inchldii_g
replacenlent
of filter
cartridges.
•
Do
not
use
with
water
that
is micr()biologically
unsate
or of tmki_()wn
tluality
without
adetluate
disinfl_ction
before
or
atter
the
sysfeln.
Svsfelns
certified
for
cyst reduction
inav
be
used
on disilffecfed
wafer
that
inav
c(mfain
filterable
c_:sfs.
•
The
COlmmfilmnfs
or other
substances
rem()ved
or reduced
bv this
wafer
treafn_ent
svsfeln
are
not
necessarily
in your
wafer.
•
Check
fi)r compliance
with
the
state
and
local
laws and
regtflations.
•
Note
that
while
the
testing
was perfl)i_ned
trader
standard
laboratory
conditions,
actual
perfl)rnmi_ce
inav
vary.
Svstelns
must
be
installed
and
operated
in accordance
with
malmlhcturer's
reconm/ended
procedures
and
gtfidelines.
System Tested and (i( rtified by NSF International
against ANSI/NSF
Standard
42 & :)a f
tile
reduction
of:
Standard
No.
42: Aesthetic
Effects
Chemic_d
l nit
Taste
and
Odor
Reduction
Chlorine
Reduction
Mechanical
Fihration
Lnit
Particulate
Reduction,
Class
I
Stmldard
No.
53: HeMth
Effects
ChcmicM
Reduction
Lnit
Lead
and
Atrazine
Reduction
Lindane
and
2,4-I)
Reduction
Mechanical
Fihration
Unit
Turbiditv
Reduction
Cyst and
Asbestos
Reduction
Mmmfi_ctur(d
fin-: Gent ral Eh cwi( Coral)any, I.ouisvilh,
KY 40225
40