OPERATING
THE
GENERATOR
Startin ine
Disconnect
all electrical
loads from the generator.
Use the
following start
instructions:
I.
Make sure unit is on a level surface.
IMPORTANT:
Failure to start and operate
unit on a level
surface will cause the unit not to start or to shut down
during operation.
2.
Turn the fuel valve to the"On"
position
(Figure 4).The
fuel valve handle
should
be vertical
(pointing
toward
the ground)
for fuel to flow.
FuelValve is shown
in the On position
3.
Start engine according to instructions
given in the
engine operator's
manual.
I
WARNING
. When
starting
engine,
pull cord slowly until resistance
is felt
and then
pull rapidly to avoid kickback.
. NEVER start or stop engine with electrical
devices
plugged
in
and turned
on.
NOTE:
If engine starts after 3 pulls but fails to run, or if
unit shuts
down during operation,
make sure unit is on a
level surface
and check for proper
oil level in crankcase.
This unit may be equipped
with a low oil protection
device.
See engine manual.
1
WARNING
DO NOT touch hot surfaces and avoid hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Code of Federal Regulation (CFR) Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark attester
is required under section 4442 of the California
Public resources code. Other states may have similar laws.
Electrical
Loads
• Let engine stabilize and warm up for a few minutes
after
starting.
• Plug in and turn on the desired
120 and/or
240 Volt AC,
single phase, 60 Hz electrical
loads.
• DO NOT connect
240Volt
loads to the 120Vo[t duplex
receptacles.
• DO NOT connect
3-phase
loads to the generator.
• DO NOT connect
50 Hz loads to the generator.
• DO NOT
OVERLOAD
THE
GENERATOR.
See
"Don't
Overload
the Generator".
CAUTION
See "Don't
Overload
Generator".
Start generator
and let engine stabilize
before
connecting
electrical
loads.
Connect
electrical
loads in OFF position,
then turn
ON for
operation.
Turn electrical
loads OFF and disconnect
from generator
before
stopping
generator.