User Manual BDL4771V
4.2.6.

Advanced option MENU

Input resolution
Note: For VGA input only.
Set the resolution of the VGA input. This is only required when the display is unable to detect the VGA input
resolution correctly.
Use UP/DOWN to toggle between
• Auto
• 1360x768
Black level expansion
Note: For Component, and HDMI (video mode) inputs only.
This feature offers deeper blacks for an even better image quality. Select a suitable black level expansion
setting to reveal more details in the dark parts of an image.
Use UP/DOWN to toggle between
• Off
• Medium
Gamma selection
Gamma is what controls the overall brightness of an image. Images which are not corrected properly can
appear too white or too dark, so controlling the gamma properly can have a huge influence on the overall
picture quality of your display.
Select a display gamma value to best suit the image and optimize image brightness and contrast.
Use the UP/DOWN button to toggle between
• 2.2
• Native
Scan mode
Note: For Component, and HDMI (video mode) inputs only.
Change the display area of the image.
Use the UP/DOWN button to toggle between
• Overscan - Displays about 95% of the original size of the image. The rest of the areas surrounding the
image will be cut off.
• Underscan - Displays the image in its original size.
Scan conversion
Note: For Component, and HDMI (video mode) inputs only.
Choose to enable or disable the IP (Interlace to Progressive) conversion function.
Use the UP/DOWN button to toggle between
• 1024x768
• 1366x768
• Low
• High
• 2.0