OPERATING INSTRUCTIONS
WINDING & UNWINDING THE
POWER CORD
Your vacuum cleaner includes
a power cord which is
automatically retractable.
To extend your power cord,
pull from side and extend
to desired length up to
the yellow mark on the
power cord. (Fig. 5)
Do not pull the power
cord beyond the red
Red
mark. When vacuuming
is finished, first switch
Fig. 5
off power and disconnect plug from
electrical outlet. Then press on cord
rewind button. If the cord does not fully
retract, pull it out again and then press
on cord rewind button.
Warning:
Hold the plug when
rewinding the cord. Do not allow the
cord to whip when rewinding.
ON/OFF SWITCH
• The On/Off switch has two different
positions.
• Push on the "I" side to turn the
vacuum ON.
• Push on the "O" side to turn the
vacuum OFF.
= OFF
= ON
USING THE UNIT AS AN UPRIGHT
• Unwind the power cord and plug into
the 120V outlet.
• Push down on the
locking button to adjust
the height of the
telescopic handle.
NOTE:
When vacuuming
deep pile carpets or hard
to vacuum carpets,
lower the angle of
the telescopic
handle (see
illustration at right)
for easier maneuverability.
USING THE UNIT AS A HAND
VACUUM
• Press the telescopic tube release
button to remove the telescopic tube.
(See Fig. 2 page 4)
• Press the floor brush release button to
remove the floor brush. (See Fig 3
page 4)
• Attach the shoulder strap to the
shoulder strap attachment point.
Yellow
(Fig. 6)
• Attach the crevice tool or the dusting
brush to the end of the hose.
Fig. 6
Warning
: After extended use, the body
of the vacuum cleaner may become hot.
When using the unit with the shoulder
strap, the unit will touch the body of the
user. Therefore, make sure that the unit
body is cool before you use with the
shoulder strap. If during use, the vacuum
gets too warm, allow it to cool before
continuing to use.
Crevice Tool
For radiators, crevices, corners,
baseboards and
between cushions.
Dusting Brush
The dusting brush is
used for the furniture,
venetian blinds,
books, lamp shades
and shelves.
TM
Intelli-Sense
Filter Monitor
TM
When the Intelli-Sense
Filter Monitor
lights up, it means that the dust cup is
full, the HEPA filter, non-woven pre-filter
or debris screen need cleaning. You
must empty the dust from the dust cup
and clean the HEPA filter, non-woven
pre-filter, or debris screen.
Also check the hose and attachments to
see if they are blocked with any debris.
If they are, unblock them.
5
OPERATING INSTRUCTIONS
Emptying the Dust Cup Container
and Cleaning / Changing the Non-
Woven Pre-Filter, HEPA Filter &
Debris Screen
Warning:
Always unplug the
unit from electrical outlet before
opening the Dust Cup (container).
Important:
Do NOT use the vacuum
without the HEPA filter in place.
Warning
After each Use -
:
Always remove Filter Assembly
and the Dust Cup Cover with
the Debris Screen, then
vigorously "TapClean" HEPA
Filter and clean Debris Screen
and Non-Woven Pre-Filter until
no more dust can be removed.
IMPORTANT, Please Note: The
"TapClean" HEPA Filter will stop most of
the tiniest dust particles from re-entering
the air you breathe. In fact it stops 99.97%
of all particles as small as 0.3 microns -
many times smaller than a human hair!!!
Because of this incredible filtration
performance, the HEPA Filter will quickly
accumulate, inside the white filter folds,
many fine dust particles that are difficult to
see but which will eventually block or
reduce your suction power - if not cleaned
properly.
1. To remove the dust cup container,
first press on the dust cup release
button (1) that is located on the dust
cup handle and at the same time
press on the dust cup release button
(2) that is on the side of the upper
housing. (Fig. 7) Then pull the dust
cup container out.
Release
Button 1
Dust
Cup
Release
Button 2
Fig. 7
2. To empty the dust
cup container,
press on the trap
door release button
that is on the back
side of the dust cup
container. (Fig. 8)
3. The HEPA filter is
located underneath the
dust cup container. (Fig.9)
Remove the Non-Woven Pre-Filter.
(Fig. 10) Remove the HEPA filter, hold
the edges and pull it out slowly.
Fig. 10
Fig. 9
4. Hold the HEPA filter
by the edges and vigorously
"TapClean" the HEPA Filter
dirty side down on a hard,
flat surface until no more
dust is observed falling out
from between the pleats of
the filter. (Fig. 11) We
recommend washing the HEPA filter
once a month or when suction
appears to be reduced. Let the HEPA
filter air dry completely for 24 hours.
5. Rinse the non-woven pre-filter and let
air dry completely for 24 hours.
6. Insert the non-woven pre-filter.
7. Reinstall the HEPA filter in the
vacuum.
8. To separate the debris screen from
Dust
the dust cup, hold the dust cup in one
Cup
hand and turn the
dust cup cover counter
clockwise and pull apart.
To clean the debris
screen, we recommend
that you rinse it under
lukewarm running water
to remove the dirt that
accumulates on it, but always allow it
to completely air dry before inserting
back into the vacuum. (Fig. 12)
6
Fig. 8
Non-Woven
Pre-Filter
HEPA
Filter
Fig. 11
Fig. 12

Advertisement

loading