Oregon Scientific EMR898A User Manual
Oregon Scientific EMR898A User Manual

Oregon Scientific EMR898A User Manual

In-out thermometer with cable-free sensor and rf clock

Advertisement

Page 1
EMR898_GB(02/05)
Oregon Scientific" In-Out Thermometer with
Cable-Free Sensor and RF Clock
Model: EMR898A
User Manual

TABLE OF CONTENTS

Introduction ................................................................................ 1
Brief Description ................................................................... 1
Safety Notes ........................................................................ 1
FCC Notice .......................................................................... 3
Declaration of Conformity .................................................... 3
Other Notices ....................................................................... 4
Key Features ............................................................................... 4
Main Unit .............................................................................. 4
Front View .................................................................... 4
Back View ..................................................................... 5
Side View ..................................................................... 5
Remote Unit ......................................................................... 6
Front View .................................................................... 6
Back View ..................................................................... 6
Remote Unit Accessories ............................................. 6
Getting Started ........................................................................... 7
Package Contents ................................................................ 7
Installing the Batteries .......................................................... 7
Unit Calibration & Reset ....................................................... 8
Placement of Units ............................................................... 9
Main Unit Temperature Readings .............................................. 10
LCD Display ......................................................................... 10
Indoor Temperature Readings .............................................. 11
Remote Temperature Readings ........................................... 12
Kinetic Wave Display .................................................... 12
Temperature Range ............................................................. 13
Maximum / Minimum Temperatures ..................................... 13
12/1/03, 10:36 AM
Adobe PageMaker 6.5C/PPC

Advertisement

Table of Contents
loading

Summary of Contents for Oregon Scientific EMR898A

  • Page 1: Table Of Contents

    Oregon Scientific“ In-Out Thermometer with Cable-Free Sensor and RF Clock Model: EMR898A User Manual TABLE OF CONTENTS Introduction ................1 Brief Description ..............1 Safety Notes ................ 1 FCC Notice ................3 Declaration of Conformity ............ 3 Other Notices ............... 4 Key Features ................
  • Page 2: Introduction

    Language Options ..............15 BRIEF DESCRIPTION Time Zone Options ............... 16 Thank you for selecting the Oregon Scientific“ In-Out Thermometer Setting the Time and Language Displays ......18 with Cable-Free Sensor and RF Clock as your personal product of Alarm Functions ..............20 choice.
  • Page 3: Fcc Notice

    Changes or modifications not expressly approved by Oregon Scientific for compliance could void the warranty and your authority to use this equipment. ¥ Take special care when handling a damaged LCD display, as the liquid crystals can be harmful to your health.
  • Page 4: Other Notices

    Increases the value of a setting. Statement of Responsibility H. RESET Hole Oregon Scientific assumes no responsibility for any incidental losses Returns all settings to default values. (such as the costs of recording or the loss of income from recording) Wall-Mount Recess Hole incurred as a result of faults with this product.
  • Page 5: Remote Unit

    REMOTE UNIT GETTING STARTED Front View PACKAGE CONTENTS A. LCD Status Display When you unpack this product, make sure to keep all the packing Displays the current temperature materials in a safe place, in case you need to later transport the device measured by the remote unit.
  • Page 6: Unit Calibration & Reset

    Remote Unit PLACEMENT OF UNITS 1. Locate the battery compartment at the back of the remote Position the remote unit and the main unit within the effective unit (→ p.6,E.). transmission range of 20 to 30 meters (65 to 100 feet). The effective range is greatly affected by building materials and NOTE 2.
  • Page 7: Main Unit Temperature Readings

    Remote Unit LCD DISPLAY Similarly, you can choose to either mount the remote unit on a wall or A. Remote Temperature make it stand on a flat surface. Displays the temperature measured by the remote unit It is recommended to place the unit away from direct sunlight, rain, (in either °F or °C).
  • Page 8: Remote Temperature Readings

    REMOTE TEMPERATURE READINGS TEMPERATURE RANGE This product is designed to work under the widest temperature ranges The remote temperature readings are displayed on the top line of the possible. However, if the temperature falls above or below the device s LCD screen display (→...
  • Page 9: Resetting Maximum / Minimum Temperatures

    Resetting Maximum / Minimum Temperatures Radio Reception Description To clear the maximum and minimum recorded temperatures: Strong reception of the U.S. Atomic Clock signal. Weak reception of the U.S. Atomic Clock signal. 1. Press and hold MEMORY for 2 seconds. The maximum and minimum temperatures No reception of the U.S.
  • Page 10: Language Options

    LANGUAGE OPTIONS Symbol Language Name States Difference English The main unit can display the weekday in five different selectable languages. Refer Eastern -5 Hours Michigan, Georgia, West Virginia, Standard Time Ohio, Virginia, Connecticut, Vermont, to Setting the Time and Language German (EST) Rhode Island, Massachusetts,...
  • Page 11: Setting The Time And Language Displays

    * These states have certain parts where a different time zone is followed. Check to make sure to set the correct time zone for your 1. Press and hold MODE for 2 seconds. area. Press MEMORY ** These states have certain areas where Daylight Savings are not observed.
  • Page 12: Alarm Functions

    ALARM FUNCTIONS To return to normal clock mode, press the MODE button NOTE anytime during the procedures below. The unit is equipped with 2 alarms: Weekday Alarm Single Alarm. Icon Type Description Setting the Alarms Weekday The Weekday Alarm will sound Monday to Friday Press to adjust the values for each setting.
  • Page 13: Other Features

    Problem Symptom Check This Remedy Press SNOOZE (→ p.5,M.) to temporarily stop the alarm. The alarm will sound again after 8 minutes unless another key on the clock is The remote Obstacles (either Move the main pressed. To stop the ringing completely, press ALARM. displayed on signal electromagnetic...
  • Page 14: Specifications

    ABOUT OREGON SCIENTIFIC the RESET Hole. Visit our website (www.oregonscientific.com) to learn more about your device and other Oregon Scientific products such as hand-held organizers, alarm clocks, and weather stations. The website also SPECIFICATIONS includes contact information for our customer service department, in case you need to reach us.