Camera housing

Advertisement

ring can be obtained from 10 BAR. If the O-ring is contaminated or suspected of being
contaminated, clean it with a cotton cloth that is free of all chemicals or contamination.
After cleaning inspect the O-ring again.
Once the O-ring has been inspected and verified fit for use, apply a
silicone grease to the O-ring. The silicone grease must be evenly distributed round the
O-ring
Replace the O-ring into the groove; run a finger round the O-ring, to make sure it is
snugly seated in the groove.
4.7 Mounting the flashlight in the housing:
Set the flashlight in normal position. Slide the flashlight all the way into the hot shoe of
the housing until it is stop (Fig. 5), Turn the lock ring follow the direction "LOCK". Take care
not to excessively tighten the screw (Fig. 6). Note: If you find that control levers do not
locate properly with the buttons, please check again that the flashlight is properly seated to
the limit of the guide rail.
(Fig. 5)
Replace the lid, remember to ensure the pressure release plug is pulled all the way out
while closing, otherwise the air cannot escape. Squeeze the lid closed all the way, you will
hear the hiss of air being expelled.
(Fig. 4) Stretch the O-ring
(Fig. 6)
6
SMALL
amount of
8/6/2006

Advertisement

loading