Battery operated backup sump pump

Advertisement

15. Replace
screen.
16. Plug in charger
to wall outlet.
17.Fill
sump
with
water
and
check
switch
action.
Adjust
tether ff necessary.
LA CAUTION ]DO NOT test run
pump
for more
than
5 seconds
without
water
in it. Running
pump
dry for
extended
periods
could
damage
pmnp
and voids
war-
fancy.
Figure 9 - Battery Hold Down Strap Buckle Threading
Craftsman Battery Backup Sump Pump
Model 390.306062
Brown -.
Black
6A
6B
¥ Clamp
y Clamp
12
/
Negative
14121194
REPAIR PARTS
LIST
Key No,
Part No.
Pert Description
1
2
3
4
5
6A
6B
7
8
9
10
11
12
PS217-5E
PS17-41
CC0030-13
U17-1148
U17-1149
PS17-100
PS 117-77A
PS22-1
PS78-3P
U78-846P
U78-876P
Switch Assembly #
Pump Complete'*"
Cord Clamp
Fuse Holder
15-Amp Time-Delay Fuse (2 supplied t)
Wire Ten,ninal (4 Red.)
Battery Terminal Clamps (2 Req,)
Battery Case (includes strap and strap brackets)
Charger'*
Check Valve
Hose Clamp 1" min. - 2" max. S.S.
Pips Adapter
Tee 1-1/2 x 1-1/2 x 1-1/4 PVC
Reducer Bushing (2 Req.)
# When ordering, also order Key Nos. 4 (Fuse Holder) and 5 (Fuse) required for installation.
* Not illustrated.
** Standard Hardware Item; purchase locally.
*** No component pads available for pump or battery charger.
t