_Hazardous
fumes. Follow cement manu-
facturer's instructions. Use PVC cement only in a well
ventilated place away from fire or flame.
11.Put clamp on adapter;, leave loose. Mount check valve in
adapter; thread assembly into tee.
12. Slip pump into check valve. Tighten clamp.
1-1/2xl -1/2xl -1/4
I
j
Tee - PVC
'{_
Pipe
Check
Valve
14640195
_--_1,----- ReducerBushing(2 Supplied)
f---1
._----
Main PumpDischargePipe
,>-__,.,
I _
I"_-- Check Valve to Prevent
i _
i
Recirculation into Sump
/____j
Figure 2B - Installation
Diagram
13. Make sure battery is fully charged;
then check operation
by disconnecting
power
to primary
sump
pump
and fill-
ing sump
until Backup Sump
Pump starts. Run Backup
Pump through
one complete
cycle.
ELECTRICAL
CONNECTIONS
AWARNING JHazardous
voltage.
Can cause
serious
or
fatal electrical
shock. Review
safety instructions,
Page 2, be-
fore operating
charger.
If your outlet
is not grounded,
install a copper
wire (at least
14 gauge)
from
the outlet
box to a cold water
pipe.
Use
ground
clamp
on pipe•
BE SURE that the cold water
pipe
used
has
metal
continuity
to electrical
ground.
Battery
charger
is double
insulated.
DO NOT modify
cord or plug.
CHARGER/BATI'ERY
INSTALLATION
NOTICE: Alarm will sound
when
charger
is first connected
to battery.
Press ALARM TEST/RESET
button
on charger.
If
alarm continues
to sound,
disconnect
one charger
lead from
the battery
and
reconnect
it. Press ALARM TEST/RESET
again; alarm will stop sounding.
1. Connect
charger
as shown
in Figure 3.
A. Connect
Positive (+) lead from charger
to positive
battery
post.
B. Connect
Negative
(-) lead from
charger
to negative
bat-
tery post.
C. Third lead from charger
is factory
connected
to lead from
pump
motor/float
gwitch.
NOTICE:
If charger
is connected
backwards,
pump
will
not operate
properly,
battery
will not charge.
2. Plug in power
cord to a 115-125 Volt AC outlet
delivering
at least 2 amps. Do not use a switch
controlled
outlet.
Mark circuit
in main power
panel
=Backup
sump pump
power
supply;
do not turn off".
3. With
charger
properly
connected
and iplugged
in, the
panel
on the front
of the charger
will appear
_ in one of
the following:
A. If battery
is dead,
charger
will supply
about
10 amps
power
(see Figure 4A).
B. If
battery
is near full charge, charger
will deliver about
5 amps power
(see Figure 4B).
C.
If battery
is fully charged,
charging
current
will be 0
amps and green
LED lamp will be lighted (see Figure
4C).
Black
Battery
Clamp
Positive
Black
t411
1194
Figure
3 - Wiring
Connections
A,
B,
CHARGING
Co
1413 1194
Figure 4 - Battery
Backup Control
Panel
A.
Battery depleted - charging current 10 amps.
B. Battery nearly charged - current about 5 amps.
C. Charge comlSlete - current 0 amps, LED lights up.