Craftsman 390.30479 Owner's Manual

Submersible sump pump

Advertisement

SE ARS
OWNER'S
MANUAL
MODELNO.
390.305001
390.304790
390.305790
CAUTION:
Read and Follow
All Safety Rulesand
Operating Instructions
Before FirstUse of
This Product.
Save ThisManual Far
Future Reference.
CRAFTSMAN Professional
Model No. 390.305001
CRAFTSMAN Professional
CRAFTSMAN Professional
Model No. 390.304790 - 1/3 HP
Model No. 390.305790 - 1/2 HP
I:RRFTJ;MRN
SUBMERSIBLE
SUMP PUMP
• Safety Instructions
• Installation
• Electrical
• Maintenance
• Repair Parts
Sears, Roebuck and Co., Hoffman Estates, IL 60179
U.S.A.
Form No.F642-9812 (Rev.3/22/05)

Advertisement

Table of Contents
loading

Summary of Contents for Craftsman 390.30479

  • Page 1 Read and Follow All Safety Rulesand Operating Instructions Before FirstUse of This Product. Save ThisManual Far Future Reference. Sears, Roebuck and Co., Hoffman Estates, IL 60179 CRAFTSMAN Professional Model No. 390.305001 CRAFTSMAN Professional Model No. 390.304790 - 1/3 HP I:RRFTJ;MRN SUBMERSIBLE SUMP PUMP •...
  • Page 2: Safety Information

    It will also help you avoid needless that result from causes we cannot in our warranty. SAFETY INFORMATION in this consult your local Sears store sttmp pnmp 6, for information remedies. When you see this 1. To avoid risk of serious bodily age, read safety pump.
  • Page 3: Installation

    Sttmp Pump Hose Kit, SEARS Stock No. 27909, 24' (7.3M) of 1-1/4" adapter and stainless atmospheres. Valve, SEARS Stock No. 2789 or 2792. Failure to follow injury and!or THE SUMP Locate sump at lowest place in basement before servicing Floor drains or drain tiles can also be tiled into sump.
  • Page 4: Operation

    NOTE: To avoid backflow into sump when pump shuts off, install a Check Valve, SEARS Stock No. 2789, in threaded dis- charge port of pump. A SEARS No. 2789 Check Valve is con- structed with an anti-airlock hole. If you use a SEARSNo. 2792 or any other check valve, drill a 1/8"...
  • Page 5: Maintenance

    DO NOT attempt to repair a non-operational Take it to Sears for service by a qualified / MAINTENANCE Sizing Generator Below is the minimum to power this pump motor. Any additional must be added to the listed load and the generator cordingly.
  • Page 6: Service Specifications

    Remove structing impeller. If pump still does not operate rectly, return it to your nearest Sears Service Department for repairs. 3. Pump runs, but does not empty sump: a. Clean pump intake screen. b. Water may be entering...
  • Page 7 SERVICE VERTICAL SWITCH REPLACEMENT Models 390.30479 and 390.30579 ® CAUTION j Make sure holds float housing; otherwise pump will not shut off. To check switch operation, run pump through one com- plete cycle after installation. A WARNINGj Risk of electrical shock.
  • Page 8: Repair Parts

    Model 390.305001 11-- 11A --I 12-- tS--A REPAIR PARTS LIST Part Description Switch Mounting Bracket Screw Cord Clip Float Rod Float Retainer Pin Float Retainer Strap Float Stop Screw Power Cord Cord Connector O-Ring Motor Housing Upper Volute Screws Impeller Volute Gasket Base Plate Lower Volute...
  • Page 10 Sears Parts & Repair Center. Call anytime, To purchase a protection agreement (U.S.A.) or maintenance agreement (Canada) on a product serviced by Sears: 1-800-827-6655 (U.S.A.) Para pedir servicio de reparaci6n...

This manual is also suitable for:

390.305001390.30579390.304790390.305790

Table of Contents