Installarion & Assembly; Installation And Assembly - Craftsman 921.153101 Owner's Manual

3-gallon 1.5 hp (max developed) 1 hp running oil lubricated air compressor
Hide thumbs Also See for 921.153101:
Table of Contents

Advertisement

Installation
& Assembly
The air compressor should be turned off and unptuggod Imm the
power coume betore any rnainrananoe is performed as well a=
the air bled from the tank and the unit allowed t_rne
to cool. Personal Inlunes could oOcvr from moving paris, elecld-
col sources, compressed elf or hot surfaces. The
mgulutor assembly must be a_eched before use, Failure to
assemble correctly could result in lo_s end poss=bleinjury
It unsure of assembly instructions or you expe(_ence diffisul_ in
the assmmb;y please call your local .service deparlmem Ior forthsr
Instruction,
Qufok Connect Assembly
'L Before assembly be sure that the
Quick Connect (Q C,) threads have a
sealant applied from the factory m proven!
Iaa_ around the threads. If no sealant is
present, wrap [ha threaded portion W_l
Teflon tope.
2 Remove the regulator's plasito plug, Attach
the O C. assembly to the air compressor by aligning the Q,C
threads to the regulator on the manifold. Be certam ld align
the threads before tlghtenleg to prevent thread damage
3, After hand t_htening, the a_embly should be turned clock
wise 1 to 1,5 revolmlona with • 13ki6ths _ze wrench.
To prevent damage and leaks, do not over-tighten
To ths'taU the Air Intake Rlter
Remove the pleatlo plug from the
_,/_
_"-'_
compressor head. Remove the air into, he
"_(
_'_
t]ifer from the poly bag and thread it onto the
t_'
j_
asr as shown.
Do not otternptto start the =drcomprasecr
without ffrst adding oil to the crankcase
Serious damage can
resuit unl_
fifled _th oil The pump Is shipped without ell from
the fectury. Only use non.detergent clio since multl-vlecos W
motor oils leave carbon itapos_
on pump ¢omp0nsms, thus
and compressor rife,
Drain the tank to I_leece all tank air
pressure betom removthg the oll _ P._p, Be sure the air vent in
the 09 fill cap (see figure to the right) ;8 free _
L_.,7_I ?L
from debris. If ntr vent Is blocked, pressure
can build In orankcase causing dam N
to
lee compressor and possPblo pereonat in_Jry.
Lubdeatton and Oil
Remove the oll tiffcap by turning it
counter-clockwise
by hand. Fd] the
compressor pump v/_h an sir €ompressor ell such as SAF.-_0
non.detergent (API CG/CD Heevy Duty) oll
at slow thterv_
unlll the oil tee0hea the
eentor of the red oirelo In the sight itiass
( see figure above). Use SAE-10 during
extreme winter ¢onditfono.
Lo_-'Mlon of the Air Compmuor
The air compressor should oiwe.ys be Io_ted In n clean,
dry. and welt verdllated environment. The unit should have
ai mNmum, 12 Inchec of space on each side, The air m_arintake
should be _ee of any debris or obstmc_ono, Check the air fi_tor
on a dally bogle to be sure _tis clean and in working order
Grounding Inatru_lone
TI_ product should be greund_. In the event of an decuir.al
sherl oh'cult, grounding reduses I_ risk of electric r.hock by pro-
vlrflngan escape wire for the eleclnfocurrant, This product is
equipped with • cord having o grounding wire with an agproprf-
ato gmun_ng plug. (See the figure below) The plug must be
plugged into an outlet that is properly installed and grounded In
acmrdanco wi_ ag lOcal codas and ordinances Check with a
quaiiflod olec_ln_n or sense
personnel ff these
ins'b'ucfions arenot
P/ug
complet$1y understood
Omunde_
or If in doubt as to
guilt
whether the tool is
Ground/no P/n
Improper install_on
of the grounding p_ugwill result In It
risk of slocMe shock. IFrepair or replecomerd of the cord
or p_ugIs nuseseery, do not conne_ the grounding w_rsto either
fiat blade fermlnaL The wire wi_ insula_on having an outer sur-
face tha_ Is green with or without yellow stripe= Is _
grounding
wire CheeX _
a quaiffled ethetri=an or serviceman If the
grounding ii%=d_.,ctin_ are not completely understood, or if m
doubt as to _i_uther the product m propedy grounded. DO not
modify the plug provided, If It will not th the oubeL havE)the prop
er ou'Jetinstalled by & qualified aiesfi'idan.
This pmduut Is for use on ,= cimuit having a nominal rot_ng
of 120 wits and is lectory-equltwed with e spa€tits aie_dc cord
und plug to pem_]t conno_lOn to a proper electric clrcolL Make
sure that the product Is connected to as outbt hav_g the same
sunfigur_gon as the plug, No adapter should be used with this
product, H theproduct mutd be reconnected for use on a differ-
ent type of eb¢_e
circuit, quailfled servlse personnel should
mske ths reconn_fion,
ExtensionCords
Useonlya 3-wire extensioncord met has e 3..blade
grounding plug.anda S-slotnmsptanlo that willacceptthe plug
onl_e predu_ Ma_e sumyoursxtanaloncordis In goodcondi-
Ifon,When usingan extanaion cord,be sureto uaeone heavy
onDugh to P.art_ the currentyourproduut w ill draw. Cordsmust
not escoed 25 feetandNo. 12 AWGsee must be ungd An
undersized cord willceu.'u= a drop in linevoltage resulting In loss
el power and overileetthg,
BrenkIn Prooedure_
NobreakIn pro_dom is requiredby the usur, T rde
product Is factory lect_ to ensureproperoperation and
performanse

Hide quick links: