Applications; Unit Location - Nordyne M1B, M1G, M1M Installation Instructions Manual

M1b, m1m, m5s, m1g, series downflow, direct vent (sealed combustion) forced air gas & oil furnaces
Table of Contents

Advertisement

6" (152 mm)
Top Clearance
0" Side
Clearance
to Furnace
Cabinet
Figure 1. Alcove Installation
6" (152 mm)
Top Clearance
0" Side
Clearance
to Furnace
Cabinet
Figure 2. Closet Installation
6" (152 mm)
Top Clearance
0" Side
Clearance
to Furnace
Cabinet
Figure 3. Special 1" Clearance
Blower / Motor
Assembly
Part
No.
Blower
Motor
Wheel
(Hp)
903773
10 x 8
903413
11 x 8
903890
11 x 8
Table 2. Blower Assemblies
6
Removable access
panel should be
installed above
furnace door frame
to access roof jack
Nearest
Wall or
Partition
Provide min. 235
2
sq. in. (1516 cm )
open free area in
front or side wall
or
In closet
door
located
at top,
center
or bottom
CLOSET DOOR
Provide min. 250
sq. in. (1613 cm )
2
open free area in
front or side wall
or
in closet
door
a fully
louvered
door may
be used
CLOSET DOOR
A/C Capacity
(Tons)
1/4
2, 2½ & 3
1/2
2, 2½, 3 & 4
3/4
2, 2½, 3, 4 & 5

Applications

M1 Series gas and M5 Series oil furnaces are
listed direct vent (sealed combustion), downfl ow
heating appliances for manufactured (mobile)
homes, recreational vehicles, and for use in
residential/modular/commercial construction.
The furnace must be located so that venting can
be properly achieved.
Air conditioning may be added to structures with
M1/M5 series furnaces using air conditioning or
conventional units. This Installation Instruction
manual includes special requirements for
incorporation of air conditioning equipment to the
M1/M5 series of furnaces. See Tabel 12 (page 32).
Multi-speed blower assemblies shown in Table
2, have been certifi ed for fi eld installation in M1/
M5 Series furnaces.

Unit Location

• The furnace shall be appropriately located to
the supply and return air distribution system
(See Page 7). Sides and back of the furnace
may be enclosed by wall framing. See Minimum
Clearances (page 2) and Figures 1- 3.
• The furnace installation is only intended for
free air return through the furnace door louvers.
DO NOT connect a ducted return air system
directly to the furnace. Improper installation
may create a hazard and damage equipment,
as well as void all warranties.
• Furnace may be installed on combustible
flooring when using NORDYNE Duct
Connectors. See pages 9 & 10.
• When installed in a residential garage, the
furnace must be positioned so the burners and
the source of the ignition are located no less
than 18 inches above the fl oor and protected
from physical damage by vehicles.
"A"- 56"
"A" Model
w/o Coil
Cabinet
"B" Model
w/Coil
Cabinet
Figure 4. Overall Dimensions
"B"- 76"