FURNACE
ORIFICE SIZE AND
MODEL
OUTPUT CAPACITY
Orifi ce Size - Nat. Gas
M1M/M1G
Orifi ce Size - LP
- 056
Output - MBTUH
Orifi ce Size - Nat. Gas
M1M/M1G
Orifi ce Size - LP
- 070
Output - MBTUH
Orifi ce Size - Nat. Gas
M1M - 077
Orifi ce Size - LP
Output - MBTUH
Orifi ce Size - Nat. Gas
M1G - 077
Orifi ce Size - LP
Output - MBTUH
Orifi ce Size - Nat. Gas
M1M - 090
Orifi ce Size - LP
Output - MBTUH
Orifi ce Size - Nat. Gas
M1G - 090
Orifi ce Size - LP
Output - MBTUH
Orifi ce Size - Nat. Gas
M1B - 066
Orifi ce Size - LP
Output - MBTUH
Orifi ce Size - Nat. Gas
M1B - 086
Orifi ce Size - LP
Output - MBTUH
NOTES: For Canadian high altitude (2,000 - 4,500'), reduce gas manifold pressure to 3.0" W.C. for
natural gas and 9" W.C. for LP gas. (Includes 4% Input Reduction for Each 1,000 Feet). These specs
do not apply to oil furnace installations. Reference Sources: ANSI Z233.1 & NFPA 54, National Fuel
Gas Code.
Table 11. Equivalent Orifi ce Sizes for High Altitude Installations
M1/M5*B Models and for use with Blower Kit No. 903773 1/4 Hp 3 Speed
Heating Speed
Furance Input
086, 090
066, 070, 077
56
M1/M5*C Models and for use with Blower Kit No. 903413 1/2 Hp 4 Speed
Heating
Furance Input
Speed
Setting
077, 086, 090
056, 066, 070
M1/M5*D Models & for use with Blower Kit No. 903890 3/4 Hp 4 Speed
Heating
Furance Input
Speed
Setting
077, 086, 090
056, 066, 070
Table 12. A/C Blower Speed Selection Chart
32
SEA
2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000
LEVEL
29
29
45
46
45.4
41.8 40.1 38.5 37.0 35.5 34.1 32.7 31.4 30.2
24
25
42
42
56.7
52.3 50.2 48.2 46.2 44.4 42.6 40.9 39.3 37.7
21
23
40
41
61.7
56.9 54.6 52.4 50.3 48.3 46.4 44.5 42.7 41.0
21
23
40
41
59.9
55.2 53.0 50.9 48.9 46.9 45.0 43.2 41.5 39.8
17
18
36
37
71.7
66.1 63.5 60.9 58.5 56.1 53.9 51.7 49.7 47.7
17
18
36
37
69.7
64.2 61.7 59.2 56.8 54.6 52.4 50.3 48.3 46.3
26
27
43
44
52.6
48.5 46.6 44.7 42.9 41.2 39.6 38.0 36.5 35.0
18
19
37
38
68.2
62.9 60.3 57.9 55.6 53.4 51.2 49.2 47.2 45.3
Setting
H
M
L
2 Ton
2-1/2 Ton & 3 Ton
ML
L
L
L
2 Ton
2-1/2 Ton & 3 Ton
ML
L
L
L
ALTITUDE - FEET
30
30
30
30
47
47
47
48
26
27
27
28
43
43
43
44
23
24
25
26
42
42
42
43
23
24
25
26
42
42
42
43
19
19
20
21
38
38
39
40
19
19
20
21
38
38
39
40
28
28
28
29
44
44
45
45
19
20
21
22
39
39
40
41
Cooling Speed/ Evap Coil
2 Ton
2-1/2 Ton
L
M
L
M
L
M
Cooling Speed/ Evap Coil
3-1/2 Ton
ML
MH
ML
MH
Cooling Speed/ Evap Coil
3-1/2 Ton & 4 Ton
ML
MH
ML
MH
31
31
31
32
48
49
49
50
28
29
29
30
44
45
46
47
27
28
28
29
43
44
44
45
27
28
28
29
43
44
44
45
22
23
24
26
41
41
42
43
22
23
24
26
41
41
42
43
29
30
30
30
46
47
47
48
23
24
26
27
42
42
43
43
3 Ton
H
H
H
4 Ton
H
H
5 Ton
H
H