Inspecting Burner; Cleaning And Maintenance - Desa Comfort Glow CGP20TLB Owner's Operation And Installation Manual

Blue flame vent-free propane/lp gas heater
Table of Contents

Advertisement

OWNER'S
MANUAL
INSPECTING
BURNER
Check pilot flame pattern and burner flame
pattern often.
PILOT FLAME
PATTERN
Figure 19 shows a correct pilot flame pat-
tern. Figure 20 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.
If pilot flame pattern is incorrect, as shown
in Figure 20
• turn heater off (see To Turn Off Gas to
Appliance, page 12).
• see Troubleshooting, pages 14 through 16.
Pilot Burner
Figure 19 - Correct Pilot Flame Pattern
\
Figure 20 - Incorrect Pilot Flame Pattern
BURNER FLAME PATTERN
Figure 21 shows a correct burner flame
pattern. Figure 22 shows anincorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than 1/2 the
glass panel height.
CLEANING
AND
MAINTENANCE
WARNING: Tum off heater
I
and let cool before cleaning.
I
WARNING: If yellow tipping
occurs, your heater could pro-
duce increased levels of carbon
monoxide. If burner flame pat-
tern shows yellow tipping, follow
instructions
at bottom Qf_thjs
page.
NOTICE: Do not mistake orange
flames with yellow tipping. Dirt
or other fine particles enter the
heater and burn causing brief
patches of orange flame.
If burner flame pattern is incorrect, as shown
in Figure 22
• turn heater off (see To Turn Off Gas to
Appliance, page 12).
• seeTroubleshooting, pagesl4throughl6.
_lb CAUTION:
You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these
areas of
heater before each use. Have
_ heaterJnspectedyearlybyaq
uali-
fled service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, etc.
ODS/PILOT
AND BURNER
• Use a vacuum cleaner, pressurized air,
or small, soft bristled brush to clean.
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air
to clean.
Exterior
Use a soft cloth dampened with a mild
I'_ *L".....
Sr o;p::drr w:t:dmitxture. Wipe the cabi-
CORRECT FLAME PAI"rERN
AT HIGH POSITION
Figure 21 - Correct Burner Flame Pattern
_
Yellow
_
_Tipping
INCORRECT FLAME PATFERN
AT H_GH POSITION
Figure 22 -Incorrect Burner Flame Pattern
lO,_
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents