Desa CGP20B Owner's Operation And Installation Manual

Desa blue-flame vent-free propane/lp gas heater owner's operation and installation manual rp30e, cgp20b, cgp20lb

Advertisement

BLUE-FLAME VENT-FREE
PROPANE/LP GAS HEATER
OWNER'S OPERATION AND INSTALLATION MANUAL
RP30E
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury, or loss
of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
CGP20B
CGP20LB
WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational pro-
cedures. For assistance or ad-
ditional information consult a
qualified installer, service
agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it
is installed. Provisions for ad-
equate combustion and venti-
lation air must be provided.
Refer to Air for Combustion and
Ventilation section on page 4
of this manual.

Advertisement

Table of Contents
loading

Summary of Contents for Desa CGP20B

  • Page 1 This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. *Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer Save this manual for future reference. CGP20B CGP20LB WARNING: Improper installa- tion, adjustment, alteration, ser- vice, or maintenance can cause injury or property damage.
  • Page 2: Safety Information

    BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER SAFETY INFORMATION WARNINGS IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, elec- trical shock, and carbon monox- ide poisoning.
  • Page 3: Product Identification

    PRODUCT IDENTIFICATION Front Panel Figure 1 - Vent-Free Propane/LP Gas Heater LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANS Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
  • Page 4: Air For Combustion And Ventilation

    BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and venti- lation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.
  • Page 5: Determining Fresh-Air Flow For Heater Location

    AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
  • Page 6 BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12"...
  • Page 7: Check Gas Type

    4. If you can, provide greater clear- ances from floor, ceiling, and join- ing wall. You can locate model CGP20B and CGP20LB on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer.
  • Page 8 BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER INSTALLATION Continued INSTALLING HEATER TO WALL Mounting Bracket Locate mounting bracket in heater carton. Remove mounting bracket from heater carton. Figure 5 - Mounting Bracket Location Removing Front Panel Of Heater 1. Remove two screws near bottom cor- ners of front panel.
  • Page 9 INSTALLATION Continued Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep. 2.
  • Page 10: Connecting To Gas Supply

    BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER INSTALLATION Continued CONNECTING TO GAS SUPPLY WARNING: This appliance re- quires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator. WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. CAUTION: Never connect heater directly to the propane/LP supply.
  • Page 11: Checking Gas Connections

    INSTALLATION Continued CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
  • Page 12: Lighting Instructions

    BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER OPERATING HEATER Continued LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on page 11, column 3. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise to the OFF position. Wait five (5) minutes to clear out any gas.
  • Page 13: Inspecting Burner

    INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pat- tern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool.
  • Page 14: Troubleshooting

    BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER TROUBLESHOOTING Note: For additional help, visit DESA International’s technical service web site at www.desatech.com. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM When ignitor button is pressed, there is no spark at ODS/pilot...
  • Page 15 TROUBLESHOOTING Continued OBSERVED PROBLEM Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit White powder residue forming within burner box or on adjacent walls or furniture 104412 OWNER’S MANUAL POSSIBLE CAUSE...
  • Page 16 BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER TROUBLESHOOTING Continued WARNING: If you smell gas WARNING ICON G 001 • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
  • Page 17: Specifications

    PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see page 23) or call DESA International’s Technical Service Depart- ment at 1-800-323-5190. When calling, have ready • your name •...
  • Page 18: Illustrated Parts Breakdown

    BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER ILLUSTRATED PARTS BREAKDOWN RP30E 10-1 10-2 ODS/PILOT 104412...
  • Page 19: Parts List

    PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. RP30E 104412 PART NUMBER DESCRIPTION 098304-01 Screw, #10 x 3/8" 098345-01AC Front Panel 103476-02 Grill Guard 101108-01...
  • Page 20 BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER ILLUSTRATED PARTS BREAKDOWN CGP20B CGP20LB 12-1 12-2 ODS/PILOT 104412...
  • Page 21 Cabinet, Ivory (CGP20LB Only) 097159-04 Piezo Ignitor 098276-01 1/8" NPT Plug 098354-01 Control Knob 098508-01 Valve Retainer Nut PARTS AVAILABLE — NOT SHOWN 098306-02 Control Position Decal (CGP20B) 098306-03 Control Position Decal (CGP20LB) 103571-01 Operating Instructions Decal 100642-01 Assembly, Hardware QTY.
  • Page 22 Purchase these heater accessories from your local dealer. If they can not supply these accessories, either contact your nearest Parts Central or call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the ad- dress listed on the back page of this manual.
  • Page 23: Parts Centrals

    PARTS CENTRALS Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-800-362-6951 sales@portableheaterparts.com techservice@portableheaterparts.com 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com...
  • Page 24: Warranty Information

    COMFORT GLOW VENT-FREE HEATERS DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.