Problem
LED
Description
State
Alarm sounds
BCC and
when BCC is
system fault
inserted
LEDs flash
EMS reports
Disk module
critical errors
LED is on or
off
IOSCAN (HP-
On or off
UX) lists disk
as NO_HW, or
Mapper or
DSTAT ALL
(MPE/iX) lists
no device type
SCSI cable is
Bus active
connected but
LED is off
corresponding
LED is off
Probable Cause/Solution
Internal or external DIP switches on the new BCC do not match
the DIP switch settings on the installed BCC.
Use diagnostic utilities (STM or Sysdiag) to determine disk status.
Depending on the results, monitor or replace disk module.
– Disk module is faulty. Replace.
– Backplane is faulty. Replace.
– If the all disks on the bus have this problem, the cable is faulty.
Replace the cable.
– If all disks in the disk system have this problem, the BCC is
faulty. Replace the BCC.
– The host is not on.
– The disk system is connected in an invalid configuration.
Reconnect in a valid configuration (see chapter 3).
– The HBA is faulty. Troubleshoot the HBA.