Problem
HWEvent
Description
Category
Disk fault
Critical
LED is on
Power supply
Critical
LED is amber
Fan LED is
Critical
amber
LCC fault
Critical
LED is on
LCC fault
none
LED is on
and the disk
system beeps
GBIC fault
Critical
LED is on
100
Status
LED
State
SAM
Fault
Critical
(See STM
LED on
Disk Tool)
Amber
Critical
Critical
Amber
Critical
Critical
LCC
Critical
Critical
Fault
LED on
LCC
none
none
Fault on
Tx Fail
none
none
LED on
STM
Probable Cause/Solution
Disk hardware is faulty. Replace the
disk.
– An incompatible or defective
component caused a temporary
fault.
– Power supply hardware is faulty.
Unplug the power cord and wait for the
LED to turn off. Reinsert the power
cord. If fault persists, replace the power
supply.
Fan has slowed or stopped. Replace
the fan.
LCC hardware is faulty. Replace the
LCC.
The Enclosure ID on the installed LCC
does not match the Enclosure ID on the
peer LCC. Reset the Enclosure ID and
reinsert the LCC.
– GBIC transmission circuit has failed.
– GBIC is not receiving power.
Reseat the GBIC. If problem persists,
replace GBIC. If the replacement GBIC
fails, contact HP technical support.