HP Surestore Disk Array 12h - And FC60 Configuration Manual page 30

Operating system configuration guide
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Enter enable
Enter desired queue depth
Enter yes
Exit the fx utility
Enter yes
30
fx/label/set/parameters: Auto bad block reallocation (write) = (enabled)
fx/label/set/parameters: Auto bad block reallocation (read) = (enabled)
fx/label/set/parameters: Read ahead caching = (enabled)
fx/label/set/parameters: Write buffering = (enabled)
fx/label/set/parameters: Drive disable prefetch = (0)
fx/label/set/parameters: Drive minimum prefetch = (0)
fx/label/set/parameters: Drive maximum prefetch = (0)
fx/label/set/parameters: Drive prefetch ceiling = (0)
fx/label/set/parameters: Enable CTQ = (disabled) enable
fx/label/set/parameters: CTQ depth = (2) 8
fx/label/set/parameters: Read buffer ratio = (0/256)
fx/label/set/parameters: Write buffer ratio = (0/256)
* * * * * W A R N I N G * * * * *
About to modify drive parameters on disk dksc(8,0,2)! ok? yes
----- please choose one (? for help, .. to quit this menu)-----
[exi]t
[d]ebug/
[b]adblock/
[exe]rcise/
fx> exi
Label info has changed for disk dksc(8,0,2). write out changes? (yes) yes
hp surestore disk array xp operating system configuration guide: SGI IRIX
[l]abel/
[a]uto
[r]epartition/

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore disk array xp