Verify New Device Recognition

Example
TID=0, LUN = 0, SCSI
controller 8
TID=0, LUN = 1, SCSI
controller 8
TID=0, LUN = 2, SCSI
controller 8
SGI IRIX Installation
To verify the system recognizes the devices on the newly installed disk array:
1. Power on the system.
2. Log in to the system as root.
3. Generate a file containing peripheral device information by entering
hinv –v > /tmp/hinv.info
4. Display peripheral device information by entering
more /tmp/hinv.info
# more /tmp/hinv.info
4 250 MHZ IP27 Processors
CPU: MIPS R10000 Processor Chip Revision: 3.4
FPU: MIPS R10010 Floating Point Chip Revision: 0.0
Main memory size: 2048 Mbytes
Instruction cache size: 32 Kbytes
Data cache size: 32 Kbytes
Secondary unified instruction/data cache size: 4 Mbytes
Integral SCSI controller 2: Version Fibre Channel AIC-1160, revision 2
Integral SCSI controller 0: Version QL1040B (rev. 2), single ended
Disk drive: unit 1 on SCSI controller 0
CDROM: unit 6 on SCSI controller 0
Integral SCSI controller 1: Version QL1040B (rev. 2), single ended
Integral SCSI controller 3: Version Fibre Channel AIC-1160, revision 2
Integral SCSI controller 4: Version Fibre Channel AIC-1160, revision 2
Integral SCSI controller 5: Version Fibre Channel AIC-1160, revision 2
Integral SCSI controller 6: Version Fibre Channel AIC-1160, revision 2
Integral SCSI controller 8: Version Fibre Channel QL2200
Disk drive: unit 0 on SCSI controller 8
Disk drive: unit 0, lun 1 on SCSI controller 8
Disk drive: unit 0, lun 2 on SCSI controller 8
Disk drive: unit 0, lun 3 on SCSI controller 8
Disk drive: unit 0, lun 4 on SCSI controller 8
Disk drive: unit 0, lun 5 on SCSI controller 8
Disk drive: unit 0, lun 6 on SCSI controller 8
Disk drive: unit 0, lun 7 on SCSI controller 8
Disk drive: unit 0, lun 8 on SCSI controller 8
Disk drive: unit 0, lun 9 on SCSI controller 8
Disk drive: unit 0, lun 10 on SCSI controller 8
Disk drive: unit 0, lun 11 on SCSI controller 8
Disk drive: unit 0, lun 12 on SCSI controller 8
Disk drive: unit 0, lun 13 on SCSI controller 8
Disk drive: unit 0, lun 14 on SCSI controller 8
Disk drive: unit 0, lun 15 on SCSI controller 8
Integral SCSI controller 7: Version Fibre Channel AIC-1160, revision 2
IOC3 serial port: tty1
IOC3 serial port: tty2
Integral Fast Ethernet: ef0, version 1, module 1, slot io1, pci 2
Origin FIBRE CHANNEL board, module 1 slot 8: Revision 4