Brocade Communications Systems StoreFabric SN6500B Troubleshooting Manual page 43

Brocade fabric os troubleshooting and diagnostics guide v7.1.0 (53-1002751-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

2. Look for the device in the NS list, which lists the nodes connected to that switch. This allows
3. Enter the portLoginShow command to check the port login status.
4. Enter the fcpProbeShow command to display the FCP probing information for the devices
5. Check the port log to determine whether or not the device sent the FLOGI frame to the switch,
Fabric OS Troubleshooting and Diagnostics Guide
53-1002751-01
Connection problems
*N
021a00;
2,3;20:00:00:e0:69:f0:07:c6;10:00:00:e0:69:f0:07:c6; 895
Fabric Port Name: 20:0a:00:60:69:10:8d:fd
NL
051edc;
3;21:00:00:20:37:d9:77:96;20:00:00:20:37:d9:77:96; na
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee0;
3;21:00:00:20:37:d9:73:0f;20:00:00:20:37:d9:73:0f; na
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee1;
3;21:00:00:20:37:d9:76:b3;20:00:00:20:37:d9:76:b3; na
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee2;
3;21:00:00:20:37:d9:77:5a;20:00:00:20:37:d9:77:5a; na
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee4;
3;21:00:00:20:37:d9:74:d7;20:00:00:20:37:d9:74:d7; na
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee8;
3;21:00:00:20:37:d9:6f:eb;20:00:00:20:37:d9:6f:eb; na
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051eef;
3;21:00:00:20:37:d9:77:45;20:00:00:20:37:d9:77:45; na
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
N
051f00;
2,3;50:06:04:82:bc:01:9a:0c;50:06:04:82:bc:01:9a:0c; na
FC4s: FCP [EMC
Fabric Port Name: 20:0f:00:60:69:10:9b:5b
you to determine if a particular node is accessible on the network.
If the device is not present in the NS list, the problem is between the device and the
switch. There may be a time-out communication problem between edge devices and the
name server, or there may be a login issue. First check the edge device documentation to
determine if there is a time-out setting or parameter that can be reconfigured. Also, check
the port log for NS registration information and FCP probing failures (using the
fcpProbeShow command). If these queries do not help solve the problem, contact the
support organization for the product that appears to be inaccessible.
If the device is listed in the NS, the problem is between the storage device and the host.
There may be a zoning mismatch or a host/storage issue. Proceed to
attached to the specified F_Port or L_Port. This information includes the number of successful
logins and SCSI INQUIRY commands sent over this port and a list of the attached devices.
and the switch probed the device.
0005]
0005]
0005]
0005]
0005]
0005]
0005]
SYMMETRIX
5267]
3
Chapter 9,
"Zoning".
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents