Ericsson Inc., at any time and without notice. Such changes will be incorporated into new editions of this manual. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose, without the express written permission of Ericsson Inc.
037 560 370 554 231 504 636 745 NOTE: Primary codes in bold are unique Ericsson codes. AUDIO/LOGIC BOARD The Audio/Logic Board provides all audio and digital processing of the receive and transmit audio for digital processing by the Logic Board. The board also contains...
LBI-38848D HARDWARE AND SYSTEM DESCRIPTION HARDWARE OPTIONS EDACS The location and placement of system hardware options The Dual Format MDX mobile radio operates in either are shown on Sheet 4 of the 800 MHz Dual Format MDX EDACS (digital) mode, or in GE-MARC (tone) mode, pro- Mobile Interconnect Diagrams.
Figure 1 - GE-MARC Block Diagram tone in order for the radio to enter the Ready mode. If no busy tone is present or if the four-tone sequence isn’t valid, the mobile will jump to the next channel in the call originate set and check for busy tone as described above.
LBI-38848D In a two-tone call, the mobile sends the collected tone Turning The Radio ON/OFF for a programmable duration. In the four-tone call, the mo- bile always sends a 90-millisecond collect tone which the The radio is turned ON/OFF by pressing the PWR repeater regenerates and sends for the correct duration.