Replacing the Lamp
5
Replace the air filter.
Place the air filter underneath the
tabs on the filter frame.
Remove the lamp
8
cage.
Remove the securing screws
from the lamp cage. Hold the
lamp cage by the handle and
pull it towards you.
Securing
screw
Resetting the lamp timer
1
Connect the power
cord.
Plug the power cord into the AC
socket of the projector.
• Reset the lamp timer only after replacing the lamp.
E-65
6
Replace the filter
cover.
Insert the tab on the end of the
filter cover into the filter cover
opening and press the filter
cover into position.
Insert the new lamp cage.
9
Press the lamp cage firmly into
the lamp cage compartment.
Fasten the securing screws.
Securing
screws
2
Reset the lamp timer.
While pressing ƒ, © and
ENTER on the projector, press
POWER ON on the projector.
7
Remove the lamp cage
cover.
Turn over the projector and
loosen the user service screw
that secures the lamp cage
cover. Then slide the cover in
the direction of the arrow.
Tab
User service screw
Attach the lamp cage
10
cover.
Slide the lamp cage cover in
the direction of the arrow. Then
tighten the user service screw.
User service screw
"LAMP 0000H" is displayed,
indicating that the lamp timer is
reset.