Sharp AY-XP08CE Operation Manual

Eco inverter split type room air conditioner
Hide thumbs Also See for AY-XP08CE:

Advertisement

Air Conditioner
INDOOR UNIT
ZIMMERGERÄT
UNITE INTERIEURE
UNIDAD INTERIOR
UNITA' INTERNA
UNIDADE INTERIOR
ΕΣΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ
BINNEN-UNIT
∑Ç ÜN∑TE
AY- XP08CE
AY- XP10CE
AY- XP13CE
R
OUTDOOR UNIT
AUSSENGERÄT
UNITE EXTERIEURE
UNIDAD EXTERIOR
UNITA' ESTERNA
UNIDADE EXTERIOR
Ε ΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ
BUITEN-UNIT
DIΩ ÜN∑TE
AE - X 08BE-c
AE - X 10BE-c
AE - X 13BE
AY - XP08CE
AY - XP10CE
AY - XP13CE
SPLIT TYPE
ROOM AIR CONDITIONER
ZWEITEILIGES
KLIMAGERÄT
CLIMATISEUR INDIVIDUEL
EN DEUX PARTIES
ACONDICIONADOR DE AIRE
DE DOBLE SERVICIO
CONDIZIONATORE D'ARIA
DA CAMERA TIPO SPLIT
AR CONDICIONADO
DE DUAS UNIDADES
ΑΙΡΚ ΝΤΙΣΙ Ν ∆ΩΜΑΤΙ Υ
ΤΥΠ Υ SPLIT
SPLIT-AIRCONDITIONER
SPL∑T KL∑MA
КОМНАТНЫЙ КОНДИЦИОНЕР
ДВУБЛОЧНОГО ТИПА
OPERATION MANUAL
BEDIENUNGSANLEITUNG
NOTICE D'UTILISATION
MANUAL DE INSTRUCCIONES
MANUALE DI ISTRUZIONE
MANUAL DE INSTRUÇÕES
ΕΓ ΕΙΡΙ∆Ι
ΛΕΙΤ ΥΡΓΙΑΣ
GEBRUIKSAANWIJZING
KULLANMA KILAVUZU
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Advertisement

Table of Contents
loading

Summary of Contents for Sharp AY-XP08CE

  • Page 1 AY - XP08CE AY - XP10CE Air Conditioner AY - XP13CE SPLIT TYPE ROOM AIR CONDITIONER ZWEITEILIGES KLIMAGERÄT CLIMATISEUR INDIVIDUEL EN DEUX PARTIES ACONDICIONADOR DE AIRE DE DOBLE SERVICIO CONDIZIONATORE D'ARIA DA CAMERA TIPO SPLIT AR CONDICIONADO DE DUAS UNIDADES ΑΙΡΚ...
  • Page 3: Table Of Contents

    ENGLISH Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product. CONTENTS • PRECAUTIONS ..........E-1 • PLASMACLUSTER OPERATION ..E-13 • PART NAMES ..........E-3 • SELF CLEAN OPERATION ....E-13 • SETTING DUST COLLECTING FILTER •...
  • Page 4: Precautions

    PRECAUTIONS CAUTIONS FOR USE Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. Do not operate the buttons with wet hand. It may cause electric shock. For safety, turn the circuit breaker off when not using the unit for an extended period of time.
  • Page 5: Part Names

    PART NAMES INDOOR UNIT 1 DUST COLLECTION FILTER (non-washable) 2 DEODORANT FILTER (washable) 3 Inlet (Air) 4 Open Panel 5 Air Filters 6 POWER SELECTOR SWITCH (only for AY-XP13CE) 7 AUX. Button 8 RECEIVER Window 9 Power Supply Cord 0 Indicator Panel q Vertical Adjustment Louvres w Horizontal Adjustment Louvres...
  • Page 6: Remote Control

    PART NAMES REMOTE CONTROL 1 TRANSMITTER 2 DISPLAY (Liquid Crystal Display) 3 DISPLAY Button 4 FULL POWER Button 5 ON/OFF Button 6 THERMO. (Thermostat) Button 7 MODE Button 8 FAN Button DISPLAY 9 ONE-HOUR OFF TIMER Button 0 TIMER ON Button (for setting the timer) FULL q TIMER OFF Button (for setting the timer) POWER...
  • Page 7: Setting Dust Collecting Filter And Deodorant Filter

    SETTING DUST COLLECTION FILTER AND DEODORANT FILTER The dust collection filter and the deodorant filter are packed as accessory of this unit. During operation of the air conditioner, the filters remove dust and tobacco smoke from the air and discharges clean air. Take out the air filters.
  • Page 8: Using The Remote Control

    USING THE REMOTE CONTROL LOADING BATTERIES Use two size-AAA (R03) batteries. Remove the remote control cover. Remote control cover Insert batteries in the compart- ment, making sure the ± and — polarities are correctly aligned. • The display indicates "AM 6:00"...
  • Page 9: Set Current Clock Time

    CAUTION • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. • Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal.
  • Page 10: Basic Operation

    BASIC OPERATION Press the MODE button to select the op- eration mode. AUTO HEAT COOL DRY FAN ONLY Press the ON/OFF button to start opera- tion. • The red OPERATION lamp ( ) on the unit will light. DISPLAY Press the THERMO. button to set the de- sired temperature.
  • Page 11: Tips About Indicator Panel

    TIPS ABOUT AUTO MODE In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature and outdoor temperature when the unit is turned on. Modes and Temperature Settings the figures in ( ) are temperature settings During operation, if the outdoor temperature changes, the temperature settings will automati- cally slide as shown in the chart.
  • Page 12: Adjusting The Air Flow Direction

    ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION The air flow direction is automatically preset in each mode as follows for optimum comfort: COOL and DRY modes Horizontal air flow FAN ONLY and HEAT modes Diagonal air flow HOW TO ADJUST THE AIR FLOW DIRECTION Adjustment range Press the SWING button on the remote control once.
  • Page 13: Full Power Operation

    FULL POWER OPERATION In this operation, the air conditioner works at maximum power to makes the room cool or warm so rapidly that you can use it just after you come home. To activate the FULL POWER operation, press the FULL POWER button during operation.
  • Page 14: Tips About Plasmacluster Operation

    TIPS ABOUT PLASMACLUSTER OPERATION The ionizer inside the air conditioner will release cluster ions, which are collective mass of positive and negative ions, into the room. The cluster ions eliminate airborne mold fungus and deodorize / decompose odor-causing molecules. Ionizer Mold fungus Cluster ions Odor...
  • Page 15: Plasmacluster Operation

    PLASMACLUSTER OPERATION You can choose PLASMACLUSTER AUTO OPERATION, AIR CLEAN OPERATION or REFRESHING OPERATION During operation, press the PLASMACLUSTER button to select the mode. PLASMACLUSTER AUTO AIR CLEAN REFRESHING CANCEL AUTO • In the AIR CLEAN operation, the blue PLASMACLUSTER lamp on the unit will light up. •...
  • Page 16: Timer Operation

    TIMER OPERATION NOTE: Before setting the timer, make sure the clock is properly set with the current time. TIMER OFF Press the TIMER OFF ( ) button. The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time.
  • Page 17: Timer On

    TIMER ON Press the TIMER ON ( ) button. The TIMER ON indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the de- sired time. (The time can be set in 10-minute increments.) Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button.
  • Page 18: Auxiliary Mode

    AUXILIARY MODE Use this mode when the remote control is not available. TO TURN ON Lift the front panel of the indoor unit and press the AUX. button on the operation panel. • The red OPERATION lamp ( ) on the unit will light and the unit will start operating in the AUTO mode.
  • Page 19: Additional Notes On Operation

    ADDITIONAL NOTES ON OPERATION OPERATING TEMPERATURE RANGE • The built-in protective de- INDOOR TEMP. OUTDOOR TEMP. vice may prevent the unit 32˚C D.B. 43˚C D.B. from operating when used upper limit 23˚C W.B. out of this range. COOLING 21˚C D.B. 21˚C D.B.
  • Page 20: Maintenance

    MAINTENANCE Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance. CLEANING THE FILTERS The air filters should be cleaned every two weeks. TURN OFF THE UNIT REMOVE THE FILTERS 1 Lift the open panel.
  • Page 21 CLEANING THE DEODORANT FILTER (GREEN) The filter should be cleaned every 3~6 months REMOVE THE AIR FILTERS CLEAN THE DEODORANT FILTER 1 Take off the deodorant filter from the air filters. 2 Soak the deodorant filter in mild detergent dilution for 10 to 20 minutes. Rinse thoroughly with water, dry completely Filter stopper under sunlight.
  • Page 22: Before Calling For Service

    BEFORE CALLING FOR SERVICE The following conditions do not denote equipment malfunctions UNIT DOES NOT OPERATE SWISHING NOISE The soft, swishing noise is the sound of the The unit will not operate if it is turned on immediately refrigerant flowing inside the unit. after it is turned off.
  • Page 24 SHARP CORPORATION OSAKA, JAPAN Printed in Thailand TINSEA262JBRZ TL 02AO 1...

This manual is also suitable for:

Ay-xp10ceAy-xp13ceAe-x08be-cAe-x10be-cAe-x13be