Sharp AY-XP07ER Operation Manual

Sharp AY-XP07ER Operation Manual

Eco inverter split type room air conditioner
Hide thumbs Also See for AY-XP07ER:

Advertisement

Air Conditioner
• Uses ozone layer friendly refrigerant R410A.
• Utilise un réfrigérant qui n'attaque pas la couche
d'ozone, le R410A.
• Utiliza refrigerante R410A que no daña la capa de
ozono.
• Utilizza il refrigerante R 410A che non danneggia il
buco nell'ozono.
• Usa refrigerante R410A amigo da camada de ozono.
• ρησιµ π ιεί ψυκτικ
R410A α λα ές για τ
στρώµα τ υ
ντ ς.
• Использует охладитель R-410A безвредный
для озонового слоя.
INDOOR UNIT
UNITE INTERIEURE
UNIDAD INTERIOR
UNITA' INTERNA
UNIDADE INTERIOR
ΕΣΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ
DZENHTZZBQ ;KJR
AY- XP07ER
AY- XP09ER
AY- XP12ER
R
OUTDOOR UNIT
UNITE EXTERIEURE
UNIDAD EXTERIOR
UNITA' ESTERNA
UNIDADE EXTERIOR
Ε ΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ
ZFHEÖZBQ ;KJR
AE- X07ER
AE- X09ER
AE- X12ER
AY-XP07ER
AY-XP09ER
AY-XP12ER
SPLIT TYPE
ROOM AIR CONDITIONER

OPERATION MANUAL

CLIMATISEUR INDIVIDUEL
EN DEUX PARTIES
NOTICE D'UTILISATION
ACONDICIONADOR DE AIRE
DE DOBLE SERVICIO
MANUAL DE INSTRUCCIONES
CONDIZIONATORE D'ARIA
DA CAMERA TIPO SPLIT
MANUALE DI ISTRUZIONE
AR CONDICIONADO
DE DUAS UNIDADES
MANUAL DE INSTRUÇÕES
ΑΙΡΚ ΝΤΙΣΙ Ν ∆ΩΜΑΤΙ Υ
ΤΥΠ Υ SPLIT
ΕΓ ΕΙΡΙ∆Ι
ΛΕΙΤ ΥΡΓΙΑΣ
КОМНАТНЫЙ КОНДИЦИОНЕР
ДВУБЛОЧНОГО ТИПА
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Advertisement

Table of Contents
loading

Summary of Contents for Sharp AY-XP07ER

  • Page 1: Operation Manual

    Air Conditioner AY-XP07ER AY-XP09ER AY-XP12ER SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL CLIMATISEUR INDIVIDUEL EN DEUX PARTIES NOTICE D'UTILISATION ACONDICIONADOR DE AIRE DE DOBLE SERVICIO MANUAL DE INSTRUCCIONES CONDIZIONATORE D'ARIA DA CAMERA TIPO SPLIT MANUALE DI ISTRUZIONE • Uses ozone layer friendly refrigerant R410A. •...
  • Page 2: Table Of Contents

    ENGLISH Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product. CONTENTS • PRECAUTIONS ........E-1 • SELF CLEAN OPERATION ....E-12 • PART NAMES ........... E-3 • TIPS ABOUT PLASMACLUSTER OPERATION ........E-13 •...
  • Page 3: Precautions

    PRECAUTIONS CAUTIONS FOR USE Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. Do not operate the buttons with wet hand. It may cause electric shock. For safety, turn the circuit breaker off when not using the unit for an extended period of time.
  • Page 4: Part Names

    PART NAMES INDOOR UNIT 1 Inlet (Air) 2 PLASMACLUSTER Lamp (blue, green) 3 DEODORANT DUST COL- LECTION FILTER (non-washable) 4 Open Panel 5 Air Filters 6 AUX. Button 7 Indicator 8 Power Supply Cord 9 Vertical Adjustment Louvres 0 Horizontal Adjustment Louvres q Outlet (Air) w RECEIVER Window...
  • Page 5: Remote Control

    PART NAMES REMOTE CONTROL 1 TRANSMITTER 2 DISPLAY (Liquid Crystal Display) 3 PLASMACLUSTER Button 4 DISPLAY Button 5 ON/OFF Button 6 THERMO. (Thermostat) Button 7 FULL POWER Button 8 PROGRESSIVE AIRFLOW Button 9 MODE Button 0 TIMER ON Button (for setting the timer) DISPLAY q TIMER OFF Button (for setting the timer) w ONE-HOUR OFF TIMER Button...
  • Page 6: Setting Deodorant Dust Collecting Filter

    SETTING DEODORANT DUST COLLECTION FILTER The deodorant dust collection filters are packed as accessory of this unit. During operation of the air conditioner, the filters remove dust and tobacco smoke from the air and discharges clean air. Take out the air filters. 1 Open the open panel.
  • Page 7: Using The Remote Control

    USING THE REMOTE CONTROL LOADING BATTERIES Use two size-AAA (R03) batteries. Remove the remote control cover. Remote control cover Insert batteries in the compart- ment, making sure the ± and — polarities are correctly aligned. • The display indicates "AM 6:00"...
  • Page 8: Set Current Clock Time

    CAUTION • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. • Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal.
  • Page 9: Basic Operation

    BASIC OPERATION Press the MODE button to select the op- eration mode. AUTO HEAT COOL Press the ON/OFF button to start opera- tion. • The red OPERATION lamp ( ) on the unit will light. Press the THERMO. button to set the de- sired temperature.
  • Page 10: Tips About Indicator Panel

    TIPS ABOUT AUTO MODE In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature and outdoor temperature when the unit is turned on. Modes and Temperature Settings outdoor (¡C) temp. Cool Cool Cool ( 4¡C) ( 5¡C) ( 6¡C)
  • Page 11: Adjusting The Air Flow Direction

    ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION The air flow direction is automatically preset in each mode as follows for optimum comfort: COOL and DRY modes Horizontal air flow HEAT mode Diagonal air flow HOW TO ADJUST THE AIR FLOW DIRECTION Adjustment range Press the SWING button on the remote control once.
  • Page 12: Progressive Airflow

    PROGRESSIVE AIRFLOW Press the Progressive Air Flow button during cooling or dry operation when you do not want to feel cold air. Vertical adjustment louvre is set obliquely upward to deliver cool air to the ceiling. Press the button during heating operation. Vertical adjustment louver is set downward to deliver the warm air down to the floor and warm you.
  • Page 13: One-Hour Off Timer

    ONE-HOUR OFF TIMER When the ONE-HOUR OFF TIMER is set, the unit will stop operating after one hour. Press the ONE-HOUR OFF TIMER button. • The remote control displays “ ”. • The orange TIMER lamp ( ) on the unit will light up. •...
  • Page 14: Tips About Plasmacluster Operation

    TIPS ABOUT PLASMACLUSTER OPERATION The Plasmacluster Ion generator inside the air conditioner will release Plasmacluster ions, which are collective mass of positive and negative ions, into the room. The Plasmacluster ions reduce airborne mold fungus. AIR CLEAN OPERATION Plasmacluster ions released into the air will reduce Plasmacluster Ion generator airborne mold fungus.
  • Page 15: Timer Operation

    TIMER OPERATION NOTE: Before setting the timer, make sure the clock is properly set with the current time. TIMER OFF Press the TIMER OFF ( ) button. The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time.
  • Page 16: Timer On

    TIMER ON Press the TIMER ON ( ) button. The TIMER ON indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time. (The time can be set in 10- minute increments.) Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button.
  • Page 17: Auxiliary Mode

    AUXILIARY MODE Use this mode when the remote control is not available. TO TURN ON Lift the front panel of the indoor unit and press the AUX. button on the operation panel. • The red OPERATION lamp ( ) on the unit will light and the unit will start operating in the AUTO mode.
  • Page 18 MAINTENANCE CLEANING THE UNIT AND THE REMOTE CONTROL • Wipe them with a soft cloth. • Do not directly splash or pour water on them. We can cause electrical shock or equipment damage. • Do not use hot water, thinner, abrasive powders or strong solvents. MAINTENANCE BEFORE MAINTENANCE AFTER AIR AIR CONDITIONER SEASON...
  • Page 19 MAINTENANCE CLEANING THE INTERIOR OF AIR CONDITIONER UNIT Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker. REMOVE THE VERTICAL ADJUSTMENT LOUVRE 1 Pull the left cover open. 2 Open the lower louver slightly Left Cover and rotate the upper louvre un- Vertical Adjustment Louvre...
  • Page 20: Additional Notes On Operation

    ADDITIONAL NOTES ON OPERATION OPERATING TEMPERATURE RANGE • The built-in protective de- INDOOR TEMP. OUTDOOR TEMP. vice may prevent the unit 32˚C D.B. 43˚C D.B. from operating when used upper limit 23˚C W.B. out of this range. COOLING 21˚C D.B. 21˚C D.B.
  • Page 21: Before Calling For Service

    BEFORE CALLING FOR SERVICE The following conditions do not denote equipment malfunctions SWISHING NOISE UNIT DOES NOT OPERATE The soft, swishing noise is the sound of the refrig- The unit will not operate if it is turned on immediately erant flowing inside the unit. after it is turned off.
  • Page 22 Dj bcgjkztzbt Cnfnmb % Pfrjzf Hjccbqcrjq Atlthfwbb >J pfobnt ghfd gjnht,bntktq˜6 f nfröt Erfpf Ghfdbntkmcndf Hjccbqcrjq Atlthfwbb 1 /”= jn !& b.zy !))/ u7 ecnfzfdkbdftncy chjr ckeö,s lfzzjq vjltkb – / ktn c vjvtznf ghjbpdjlcndf ghb eckjdbb bcgjkmpjdfzby d cnhjujv cjjndtncndbb c bzcnherwbtq gj ärcgkefnfwbb b ghbvtzytvsvb ntüzbxtcrbvb cnfzlfhnfvb7 Cnhfzf–bpujnjdbntkm5 Ghjbpdtltzj d Rbnft...