INSTALLATION
LOCATING YOUR
GAS STOVE
1) When selecting a location for your stove,
ensure that the clearances outlined on this
page are met.
2) Provide adequate clearances for servic-
ing.
3) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
fl ooring, the appliance must be installed on
a metal or wood panel extending the full
width and depth of the appliance.
4) The G33R-1 Direct Vent Gas Fireplace
can be installed in a recessed position or
framed out into the room as in A, B, C, D.
See Diagram 1.
5) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The G33R-1 Direct Vent Gas Fireplace is
approved for alcove installations, which
meet the clearances listed on this page.
7) We recommend that you plan your instal-
lation on paper using exact measurements
for clearances and fl oor protection before
actually installing this appliance. Have a
qualifi ed inspector, dealer, or installer review
your plans before installation.
Diagram 1
A) Flat on Wall
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner
Note: For vent terminations see page 9.
6
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut
or weakened during installation.
2) Ensure proper grounding using the #8 ground
lug provided. See page 26.

UNIT DIMENSIONS

UltraGlow G33R-1 Zero Clearance Rear Vent Direct Vent Gas Fireplace

CLEARANCES

The clearances listed below are Minimum
distances unless otherwise stated:
A major cause of chimney related
fi res is failure to maintain required
clearances (air space) to combus-
tible materials. It is of the greatest
importance that this fi replace and
vent system be installed only in ac-
cordance with these instructions.
Clearance to Combustibles from:
Back
0"
Side
0"
Floor
0"
NOTE: The minimum fl oor clearance must be
maintained from the top surface of the carpet-
ing, tile, etc.
Minimum Clearance from Top of Unit to:
Mantel*
min. 7" (177mm)
Ceiling
30"
from top of unit.
* see mantle clearance instructions (page 7).
Side Wall Clearance
Bay or Flush Front 7-1/2"
Vent
Flex
1-1/2"
Simpson Dura-Vent 1-1/4"
Alcove Clearances:
Max. Depth
36"
Min. Width
48"
Min. Height
59"
WARNING
Clearances Flush Front
Fire hazard is an extreme risk
if these clearances are
not adhered to.
The HeatWave Duct Kit has different clear-
ance and framing requirements, check the
HeatWave manual for details.
(0mm)
(0mm)
(0mm)
(762mm)
(191mm)
(38mm)
(32mm)
(914mm)
(1219mm)
(1499mm)