I/O Monitor Screen - Epson RC170 Manual

Epson rc170 printer operator panel
Hide thumbs Also See for RC170:
Table of Contents

Advertisement

4. Operation
The display is refreshed every 0.5 seconds. Lines having a short processing time may not be
displayed, or the same line number is visible all the time even if operations are actually
being performed normally. This, however, is not a malfunction.
The following task states are displayed:
Run
Wait
Halt
Pause
Error

4.5 I/O Monitor Screen

In the I/O Monitor screen, you can monitor the I/O input, I/O output and memory I/O states.
By confirming these signals, you can gain hints for specifying the cause when the robot has
stopped due to a signal or interlock standby.
You can select between a screen that displays 32 bits worth of I/O states and a screen that
displays eight bits worth of I/O states. In the 8-bit display, the remote setting and I/O label
assigned to each bit is also displayed.
I/O Monitor screen (32-bit display)
20
The task is being executed.
The task is standing for a sensor or a timer.
The task has halted.
The task indicates that the robot motion is paused.
An error has occurred in the task.
OP1 Rev.1a

Advertisement

Table of Contents
loading

This manual is also suitable for:

Op1

Table of Contents