BACKGUARD KITS:
Model PRD3030 is shipped standard with a 9"Low backguard. High Shelf backguards, Island Trims and
the Low Back for Model PRD3630 must be ordered separately. Specific instructions for installation of
the High Shelf backguard, Low backguard or Island Trim Backguard can be found packaged with the
backguard. All backguards or island trims must be installed on the range before the unit is pushed
into the cabinet. A backguard must be installed when there is less than a 12" clearance between
combustibles and the back of the range (above the cooking surface). See fig. 12. Refer to page 3 for
backguard model numbers.
ELECTRICAL CONNECTIONS
PRD3630 model
Always disconnect electric supply cord from the wall outlet or service disconnect before servicing this
appliance. Observe all governing codes and ordinances when grounding, in absence of which, observe
National Electrical Code ANSI / NFPA No. 70-1990. The electrical supply must be a 120/240 volt, 3 wire
(plus ground) 60 Hz single phase, 50 AMP circuit. The power receptacle must be a NEMA 14-50 device
to accept the four prong plug supplied with the
unit. The receptacle should be located within the
area shown in fig. 9 page 9.
PRD3030 MODEL
The electrical supply must be a 120/240 volt, 3
wire (plus ground), 60 Hz, 30 AMP circuit. The
power receptacle must be a NEMA 14-50 device
to accept the four prong plug supplied with the
unit. The receptacle should be located within the
area shown in fig. 10, page 10.

BACKGUARD INSTALLATION

ELECTRICAL / GAS CONNECTIONS

m
from Wall
pply
Valve must be
Easily Accessible
Electrical Supply
Electrical Supply
NEMA 14-50
NEMA 14-50
Receptacle
Receptacle
Fig. 13
12