Tricity Bendix SG211X Instruction Book page 26

Table of Contents

Advertisement

Replace the nozzles of the hob burners
Before any modifications or conversion to a
kind of different gas, you must DISCONNECT
the cooker from the electricity supply and
ensure that all control knobs are in the OFF
position, and the appliance has cooled
completely.
Hob burners
Remove the pan supports;
Remove the caps and the burner crowns;
Using a No 7 socket spanner unscrew the
nozzles and replace them with those
required for the type of gas in use (see table
no. 1).
Reassemble the parts following the same
procedure in reverse.
These burners do not need any primary air
regulation.
Adjustment of minimum level for the hob
burners
The burner is correctly adjusted when the flame
is stable silent and goes out without any noise.
When changing the type of gas check that the
minimum level is correct. The air admission is
correct when the flame is about 4 mm in length.
26
The top burners do not need adjustment of
primary air.
Check that, turning the knob quickly from the
maximum position to the minimum one, the
flame does not go out.
correct
no air
adjustment
Hob burners
To adjust the minimum level:
Light the burner
Turn the knob to the position of the
minimum flame;
Remove the knob;
Unscrew or screw the by-pass screw (on
the right above of tap shaft) until a regular
small flame is reached.
For LPG screw completely the by-pass
screw.
Reassemble the parts following the same
procedure in reverse.
Check that, when turning the knob quickly
from the maximum position to the minimum
one, the flame does not go out.
excess of
air

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents