Installing Backsplash Panels

Flat Backsplash Panel
Material: Stainless
LENGTH
QTY
Inches
Millimeters
<=47
<=1193.8
1
>47 <=93
>1193.8 <=2362.2
2
>93 <=138.8 >2362.2 <=3525.5
3
>138.8 <=185
>3525.5 <=4699
4
>185<=231.3
>4699 <=5875.0
5
NOTE
Panels up to 47 in. (1193.8 mm) wide ship in one
piece; over 47 in. (1193.8 mm) in multiple pieces.
Insulated Backsplash Panel
Material: Stainless
Insulation: 1 in. (25.4 mm)
LENGTH
QTY
Inches
Millimeters
<=45
<=1143
1
>45 <=90
>1143 <=2286
2
>90 <=135
>2286 <=3429
3
WALL
>135 <=180
>3429 <=4572
4
>180 <=225
>4572 <=5715
5
LENGTH
NOTE
Panels up to 45 in. (1143 mm) wide ship in one piece;
over 45 in. (1143 mm) in multiple pieces.
10
Kitchen Hoods • Type I and Type II
WALL
HEIGHT
LENGTH
1 IN. (25.4 MM)
HEIGHT
HOOD END PANEL
SLIDE FLANGE
BEHIND BACK
OF THE HOOD
1. After the hood is hung in position, slide the flat flange
of the backsplash panel behind the back of the hood.
Note: If the backsplash panel length is greater than
45 in. (1143 mm), it will be shipped in multiple pieces.
2. After the backsplash panel has been positioned, drill
holes in the panel and fasten to the wall. (Fasteners
provided by others).
Note: The holes should be spaced to adequately
secure the panel to the wall.
3. Caulk the joints between the hood and the
backsplash panel with NSF Approved silicone caulk
(GE SCS1009, or its equivalent). The caulk is not
provided.
4. Caulk the joint between the backsplash panels when
multiple panels are required, with NSF Approved
silicone caulk (GE SCS1009, or its equivalent). The
caulk is not provided.
HOOD FRONT PANEL
BACKSPLASH PANEL
SECTION VIEW
OF BACKSPLASH
PANEL OVERLAP
®

Advertisement