Shutdown and Cleaning
Cleaning InstaClean
Filter (ProX Sprayers Only)
The InstaClean Fluid Filter prevents particles from
entering paint hose. After each use, remove and
clean it to insure peak performance.
1. Relieve pressure, page 9.
2.
a. Disconnect airless
spray hose (a) from
sprayer
b. Unscrew outlet fitting
(b).
c. Remove InstaClean
Fluid Filter (c).
3. Check InstaClean Fluid Filter (c) for debris. If
needed, clean filter with water and a soft brush.
a. Install closed
(square) end of
InstaClean Fluid
Filter (c) in sprayer.
b. Screw outlet fitting
(b) into sprayer.
312001G
Fluid
b
c
a
ti9347a
c
b
ti9347a
4. Tighten outlet fitting and
reconnect hose (a) to
sprayer. Use two
wrenches to tighten
securely.

Cleaning Gun

Clean gun fluid
filter (d) with
water or flushing
solvent and a
brush every time
you flush the
system. Replace
gun filter if
damaged.
Remove tip and guard and
clean with water or flushing
solvent. A soft brush can be
used to loosen and remove
dried on material if needed.
Wipe paint off outside of gun
using a soft cloth moistened
with water or flushing solvent.
d
ti9668a
ti11455a
(SG10)
(SG20)
ti9671a
a
ti9674a
d