The offset and return elbows may be attached
together, or a section or sections of chimney
may be used between, but do not exceed 20' in
total length between elbows. If sections of pipe
exceed 10' between elbows, a chimney stabi-
lizer must be used at the midpoint ( Figure 36 ).
The stabilizer support straps must be attached
under tension (in shear) to structural framing
members above. When two sets of elbows are
used, the maximum combined length of chim-
ney used between elbows cannot exceed 20'
( Figure 37 ). Example: If C
exceed 10'.
If an offset exceeds 6' in length, each chimney
joint beyond the first 6' of offset to the return
elbow, must be secured by a No. 8 x 1/2" sheet
metal screw located at the underside of the joint
( Figure 38 ).
A 1/8" diameter hole must be drilled in the
chimney joint using a 1/8" diameter drill. Hole
should be drilled in center of joint overlap
( Figure 39 ). Be sure to drill only through the
outer chimney casting. Do not puncture the
inner flue.
Maximum offset of chimney system is 30 . Two
offsets must not be assembled to form a 60
offset. However, two sets of offset and return
elbows may be used on a single flue system,
provided the total height of the system exceeds
25'.
Return elbow support straps must be securely
attached under tension (in shear) to structural
framing members above. Do not substitute a
FTF8-30 offset elbow in place of a FTF8-E30
return elbow.

OFFSET CALCULATIONS

Step 1. Use Offset Chart to determine amount
of horizontal offset (A) and height (B) for vari-
ous chimney section assemblies.
Step 2. Use "Height of Chimney Only" column
in The Vertical Elevation Chart to determine
combinations of chimney used above return
elbow to achieve desired heights. Reference
Components Effective Height Chart in vertical
elevation chart section.
Step 3. Use Elevation Chart as job estimator
only. Add necessary firestop spacers and stabi-
lizers as required. Firestop spacers must be
used as shown in Figures 22 and 23 and stabi-
lizers as shown in Figure 28 .
12
= 10' then C
cannot
1
2
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
FTF8 VERTICAL ELEVATION CHART
Height Of
Number Of FTF8
Chimney Only
Chimney Lengths
Inches
Feet/Inches 12" 18" 36" 48"
11
0 11
1
0
17
1
5
0
1
21
1
9
2
0
27
2
3
1
1
35
2 11
0
0
47
3 11
0
0
51
4
3
0
1
57
4
9
1
0
63
5
3
0
1
67
5
7
2
0
73
6
1
1
1
81
6
9
0
0
93
7
9
0
0
97
8
1
0
1
102
8
6
1
0
109
9
1
0
1
113
9
5
2
0
119
9 11
1
1
127
10
7
0
0
137
11
5
1
0
139
11
7
0
0
143
11 11
0
1
149
12
5
1
0
155
12 11
0
1
159
13
3
2
0
165
13
9
1
1
173
14
5
0
0
183
15
3
1
0
185
15
5
0
0
189
15
9
0
1
195
16
3
1
0
201
16
9
0
1
206
17
2
2
0
212
17
8
1
1
219
18
3
0
0
230
19
2
1
0
231
19
3
0
0
236
19
8
0
1
242
20
2
1
0
248
20
8
0
1
252
21
0
2
0
258
21
6
1
1
266
22
2
0
0
276
23
0
1
0
278
23
2
0
0
282
23
6
0
1
288
24
0
1
0
294
24
6
0
1
298
24 10
2
0
304
25
4
1
1
312
26
0
0
0
322
26 10
1
0
324
27
0
0
0
328
27
4
0
1
334
27 10
1
0
340
28
4
0
1
344
28
8
2
0
350
29
2
1
1
358
29 10
0
0
368
30
8
1
0
370
30 10
0
0
374
31
2
0
1
380
31
8
1
0
Height Of
Chimney Only
Inches
Feet/Inches 12" 18" 36" 48"
0
0
386
32
2
0
0
390
32
6
396
33
0
0
0
0
0
404
33
8
1
0
414
34
6
416
34
8
0
1
1
0
420
35
0
426
35
6
0
1
0
1
432
36
0
0
1
437
36
5
443
36 11
0
1
1
1
450
37
6
0
2
461
38
5
462
38
6
1
1
0
2
466
38 10
472
39 4
0
2
0
2
478
39 10
0
2
483
40
3
489
40
9
1
2
1
2
496
41
4
0
3
507
42
3
508
42
4
1
2
0
3
513
42
9
519
43
3
0
3
0
3
525
43
9
0
3
529
44
1
535
44
7
1
3
1
3
543
45
3
0
4
553
46
1
555
46
3
1
3
0
4
559
46
7
565
47
1
0
4
0
4
571
47
5
0
4
575
47 11
581
48
5
1
4
1
4
589
49
1
0
5
599
49 11
601
50
1
1
4
0
5
605
50
5
0
5
611
51 11
0
5
617
51
5
0
5
621
51
9
627
52
3
1
5
1
5
635
52 11
0
6
645
53
9
647
53 11
1
5
0
6
651
54
3
0
6
657
54
9
0
6
663
55
3
0
6
667
55
7
673
56
1
1
6
1
6
681
56
9
0
7
691
57
7
693
57
9
1
6
0
7
697
58
1
0
7
703
58
7
0
7
709
59
1
0
7
714
59
6
720
60
0
1
7
1
7
727
60
7
0
8
738
61
6
739
61
7
1
7
0
8
744
62
0
Number Of FTF8
Chimney Lengths
0
1
0
8
2
0
0
8
1
1
0
8
0
0
1
8
1
0
1
8
0
0
0
9
0
1
1
8
1
0
0
9
0
1
0
9
2
0
0
9
1
1
0
9
0
0
1
9
1
0
1
9
0
0
0
10
0
1
1
9
1
0
0
10
0
1
0
10
2
0
0
10
1
1
0
10
0
0
1
10
1
0
1
10
0
0
0
11
0
1
1
10
1
0
0
11
0
1
0
11
2
0
0
11
1
1
0
11
0
0
1
11
1
0
1
11
0
0
0
12
0
1
1
11
1
0
0
12
0
1
0
12
2
0
0
12
1
1
0
12
0
0
1
12
1
0
1
12
0
0
0
13
0
1
1
12
1
0
0
13
0
1
0
13
2
0
0
13
1
1
0
13
0
0
1
13
1
0
1
13
0
0
0
14
0
1
1
13
1
0
0
14
0
1
0
14
2
0
0
14
1
1
0
14
0
0
1
14
1
0
1
14
0
0
0
15
0
1
1
14
1
0
0
15
0
1
0
15
2
0
0
15
1
1
0
15
0
0
1
15
1
0
1
15
0
0
0
16
0
1
1
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bci-36Br-36Br-36-2Bri-36Bc-36

Table of Contents