Wiring Diagrams - Superior SLBV-35 Installation Instructions Manual

B-vent gas fireplaces slbv 35/40 models
Table of Contents

Advertisement

SUPERIOR
MILLIVOLT WIRING dIAGRAM
CAUTION: WHEN SERVICING CONTROLS, LABEL ALL WIRES PRIOR TO dISCONNECTION.
WIRING ERRORS CAN CAUSE IMPROPER ANd dANGEROUS OPERATION.
VERIfY PROPER OPERATION AfTER SERVICING.
B-VENT APPLIANCES ONLY: The High Limit
Switch must be factory installed in series,
as shown. If wires to this switch must be
replaced, use Type AWM 200°C - 18 gage
wire ONLY.
High Limit Switch
Control Switch*
If any of the original wire must be replaced,
use Type AWM 105º C - 18 gage wire ONLY.
_________
*Control switch options: ON/OFF wall switch, unit-mountable
ON/OFF switch, or ON/OFF remote control system (see "Accessory
Components" in the Care and Operation Instructions).
Figure 12
NOTES:
1. If any of the original wire as supplied
must be replaced, use Type AWM
105°C - 18 gage wire ONLY.
2. 120 VAC, 60 Hz - Less than 3 Amps.
CAUTION: label all wires prior to
disconnection when servicing controls.
Wiring errors can cause improper and
dangerous operation. Verify proper
operation after servicing.
* Control Switches: Wall On/Off
Switch, Unit Mounted On/Off Switch
or Remote Control Switch.
B-Vent appliances only - High limit
switch must be factory installed as
shown. If wires to this switch are
replaced, wires must be Type AWM
200°C - 18 gage wire ONLY.
CONTROL
SWITCH *
Figure 13
B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS
®
ELECTRONIC IGNITION WIRING dIAGRAM
J-Box Wiring
BK
W
G
Junction Box
TRANSFORMER 3V
HIGH LIMIT SWITCH
UNIT MOUNTED
ON/OFF SWITCH,
IF SUPPLIED
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Thermopile
Gas Control
Valve Terminals
IGNITER MODULE
3V
BLACK
BATTERY BACK-UP
ORANGE (THTP)
RED
BLACK (TP)
BROWN
GREEN (TH)
BROWN
Schematic Representation Only
See Figure 14 for detailed drawing of junction box / receptacle wiring.
_________
*Control switch options: ON/OFF wall switch, unit-mountable
ON/OFF switch, or ON/OFF remote control system (see "Accessory
Components" in the Care and Operation Instructions).
J-BOX/RECEPTACLE WIRING
J-BOX / RECEPTACLE WIRING
120V, 60Hz, 1PH
120V, 60HZ, 1PH
Junction Box
Black
OUT
IN
Tab Intact
Tab Intact
Field Wired
Factory Wired
Figure 14
Pilot Burner
Assembly
BLACK (IGNITER)
BLACK (SENSOR)
Pilot Tube
Electronic Gas Control Valve - DEXEN
HI
LO
Hot Side of
Receptacle
Neutral Side
of Receptacle
Green Ground
Screw
PILOT
13

Advertisement

Table of Contents
loading

Table of Contents