MB3887
PROCESSING WITHOUT USING OF THE ERROR AMP
When Error Amp is not used, leave FB1 terminal (pin 7) , FB2 terminal (pin 5) open and connect the INE1
terminal (pin 8) and INE2 terminal (pin 4) to GND and connect INE1 terminal (pin 9) , and INE2 terminal (pin
3) , to VREF.
"Open"
22
9
INE1
INE2
3
8
INE1
4
INE2
7
FB1
5
FB2
6
VREF
Connection when Error Amp is not used