Mode Select Parameters: Drive Parameters - Fujitsu MAP3147 Scsi Logical Interface Specifications

Scsi logical interface specifications 3.5 inch hard disk drives with internal scsi controller
Table of Contents

Advertisement

Parameter Data Formats
Bit
7
Byte
0
0
1
2-4
Default
Variable
5
Default
Variable
6-8
Default
Variable
9-11
Default
Variable
12-13
Default
Variable
14-16
Default
Variable
17
0
Default
0
Variable
0
18
Default
Variable
19
20-21
Default
Variable
22-23
Figure 4.4
Note:
When transfer of this page is requested by the MODE SENSE or MODE SENSE EXTENDED
command, the IDD reports X '16' as the page length. However, in the MODE SELECT and
MODE SELECT EXTENDED commands, if either X '16,' X '12' or X '0A' is specified, it is
treated as if the IDD has specified the correct page length. The X '12' and X '0A' page lengths
have been included in consideration of compatibility with previous models, but it is
recommended that the INIT use the X '16' page length to support expanded specifications in the
future.
4 - 18
6
5
4
0
0
0
X'16', X'12' or X'0A' (Page Length)
Cylinder Count
X'00xxxx'
X'000000'
Number of Heads
X'00xx'
X'0000'
"Write Precompensation" Starting Cylinder
X'000000'
X'000000'
"Reduced Write Current" Starting Cylinder
X'000000'
X'000000'
Drive Step Rate
X'0000'
X'0000'
Landing Zone Cylinder
X'000000'
X'000000'
0
0
0
0
0
0
0
0
0
Rotational Synchronization Offset
X'00'
X'00'
X'00' (Reserved)
Rotational Speed
X'2729' or X'3A98'
X'0000'
X'0000' (Reserved)

MODE SELECT parameters: drive parameters

3
2
1
0
1
0
0
0
RPL
0
0
0
0
0
0
0
0
(See the
"Note")
0
0
(10,025 rpm or
15,000 rpm)
C141-E167

Advertisement

Table of Contents
loading