Send Diagnostic Command: Parameter List Configuration - Fujitsu MAP3147 Scsi Logical Interface Specifications

Scsi logical interface specifications 3.5 inch hard disk drives with internal scsi controller
Table of Contents

Advertisement

3.
When a command other than the RECEIVE DIAGNOSTIC RESULTS command is linked to
this command, the execution results (response data) may no longer be secure.
Byte
Header
Page
~
~
Parameter
Figure 3.18 SEND DIAGNOSTIC command: parameter list configuration
Page code
This field specifies the code which identifies the type of parameter page being transferred from
the INIT and the operation that should be executed. The parameter pages which can be specified
by the INIT and their functions are as shown below.
Page Code (Hex)
00
40
Page parameter length
This field specifies the byte length of the page parameter after byte 4. The INIT must specify the
same value as the length specified for each of the parameter pages, which will be explained later.
Page parameter
This field specifies each of the inherent parameters in each page code. Depending on the page
code, this field may not be necessary (page parameter length = 0).
a. Page code list
C141-E167
Bit
7
6
0
1
0
0
2
3
4
~
Parameter
~
n
Reports a list of the supported page codes.
Logical/Physical Address Conversion
3.4 Maintenance, Diagnostic Commands
5
4
3
Page Code
0
0
0
Page Parameter Length (MSB)
Page Parameter Length (LSB)
Function
2
1
0
0
0
0
~
~
3 - 95

Advertisement

Table of Contents
loading

Table of Contents