Receive Diagnostic Results (1C) - Fujitsu MAP3147 Scsi Logical Interface Specifications

Scsi logical interface specifications 3.5 inch hard disk drives with internal scsi controller
Table of Contents

Advertisement

Command Specifications
SELF-TEST Code
0,0,0
Refer to clause (2), Parameter Specification.
0,0,1
The device server shall start its short self-test routine in the background mode.
0,1,0
The device server shall start its extended self-test routine in the background mode.
0,1,1
Reserved
1,0,0
Abort the current self-test running in background mode. This value is only valid if a
previous this command specified a Background self-test function and that function
has not completed. If either of these conditions is not true, then the device server
shall it respond by returning a CHECK CONDTION status.
1,0,1
The device server shall start its short self-test routine in the foreground mode.
1,1,0
The device server shall start its extended self-test routine in the foreground mode.
1,1,1
Reserved
3.4.2

RECEIVE DIAGNOSTIC RESULTS (1C)

Bit
7
Byte
0
1
2
0
3
4
5
0
This command transfers data (response data) which show the results of executing the SEND
DIAGNOSTIC command from the IDD to the INIT. The format and content of response data are
determined by the parameter list (page code) specified by the INIT in the SEND DIAGNOSTIC
command.
The "Transfer byte length" field in the CDB shows the maximum number of bytes of response data
that can be received by the INIT by this command. The IDD transfers the number of bytes of data
specified by this field or all the bytes of the effective response data, whichever is smaller in length.
Also, when zero is specified in this field, this command is terminated without anything being
transferred.
98
3 -
6
5
LUN
0
0
Transfer Byte Length (MSB)
Transfer Byte Length (LSB)
0
0
Description
4
3
2
X'1C'
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
Link
C141-E167

Advertisement

Table of Contents
loading

Table of Contents