A.1 In the Case Where Setrci Command Ended Abnormally and Displayed "Operation Failed Error Status: XX"
Remedy pattarn
Pattern A
1 Check the RCI setup procedure, the RCI address value and the connection.
1 Check the setting of the RCI address and the duplicate of the RCI address by setrci -c stat command.
2 Check whether the othr RCI host that doesn't execute the RCI initialization is connected.
2 In the case of anomaly, retry RCI setup in correct procedure.
Pattern B
1 Check the RCI address value of current unit by setrci -c stat command.
2 In the case of anomaly, retry RCI setup in correct procedure.
Pattern C
1 Check the RCI address value of current unit and other unit by setrci -c stat command.
2 In the case of anomaly, retry RCI setup in correct procedure.
Pattern D
1 Check whether 95 and more units of RCI I/O unit (include the External power controller) are not connected.
2 When 95 and more units are connected, change the connection configuration to 94 and less units (include the
External power controller), and retry RCI setup.
Pattern E
1 Replace the XSCF board.
2 After the replacement of the XSCF unit, retry RCI setup.
Pattern F
1 Check whether RCI address value of the Line selector switch is not duplicated.
2 If the duplicate, change the RCI address of the Line selector switch, and retry RCI setup. To change the RCI
address of the Line selector switch, refer to its manuals.
Pattern G
Check the state of XSCF, and execute either of the following operations.
When XSCF reboot or redundancy are working, execute the setrci command after these are completed.
If the above-mentioned doesn't correspond, retry the setrci command.