CHAPTER 1 RCI Build Procedure
1.3
RCI Setup
This section explains the RCI setup for the following cases:
New setup for a single RCI Host and two RCI I/O units
New setup of two RCI Hosts
When an RCI I/O unit is added later
When a RCI Host is added later
Remarks: Please refer to
RCI setup.
1.3.1
New setup for a single RCI Host and two RCI I/O units
Figure 1.5 New setup for a single RCI Host and two RCI I/O units
1
Log in to the XSCF Shell.
2
Execute the setrci -c stat command to display the RCI status.
XSCF> setrci -c stat
HOST
address 000f7fff
Inactive
The command completed successfully
3
Verify that the RCI address is 000f7fff.
Remarks: 000f7fff is the default value of the RCI address. If the default value is not
set, execute the setrci -c init command to initialize the value.
If the system is powered off, you can use the setrci -c init command.
1-4
Appendix A, "Troubleshooting."
RCI Host
RCI I/O unit
when there is a problem at
RCI I/O unit
C120-E361-04EN