Brother BES-1216AC Instruction Manual page 152

Electronic
Hide thumbs Also See for BES-1216AC:
Table of Contents

Advertisement

Chapter 10 Troubleshooting
Symptom
Pressor foot solenoid does not oper-
ate.
150
• Check to see if connection from the pressor foot solenoid to connector
P20 of the main PCB is proper.
• Check the resistance value of the pressor foot solenoid which does not
operate with the connector section. The normal resistance value is
approximately 80Ω.
If it is faulty, replace the solenoid with a new one. In this case, the
main PCB may also be faulty. Also replace the mainPCB with a new
one if it does not operate properly even after replacing the solenoid.
• Replace the main PCB with a new one.