Installation
of B&V Gas Vent
%1 one-stray buildings
ol %1
firs flooof
1
-so T
building_ N
Ceiling plate spacexs to centel
B-W Gas Vent m stud space -
nail _ecmely at both ends¸
width
of sttld space
to
Srads oi2
16 inch centers
Sheet metal screw base
plate to header
--Use
maimfacmrer's
method of
fastening pipe to base plate¸
Header plate of vented
wail fi_nace
(also acts as fires_p)
FIGURE B
CONTROLS
All controls are pre-assembled at the factory. The normal
mani%td pressure should be 3.5" w.c. for Natural Gas and
10" w.c. tbr L.P. Gas. The maximum inlet pressure in the
gas supply pipe should never exceed 7.0" w.c. tSr Natural
Gas or 14" w.c. for L.P. Gas. The minimum inlet pressure
in the gas supply pipe should never be lower than 4.5"
w.c. for Natural Gas or 11" w.c. tbr L.P. Gas.
Pilot Adj.
Screw
,i
ROBERTSHAW
7200ER-SO4
STANDING PILOT
FIGURE 10-A
Pilot Adj.
Screw
ROBERTSHAW
7100IPER-SO4
H.D. PILOT
FIGURE 10-B
The appliance is orificed at the factory for elevations up
to 2,000 feet. If installed above 2,000 feet, the BTU input
must be reduced 4% per 1,000 feet. See the tbllowing
orifice chart for the proper orifice %r a specific elevation.
PILOT
ADJUSTMENT
Locate the pilot adjustment screw on the valve. The pilot
flame should surround at least the top 3/8" of the powerpile
(pilot generator) or flame sensor (see Figure 8). The pilot
is unregulated so it will be operating at inlet line pressure
(maximum
7" w.c. for Natural Gas and 11" w.c. %r
Propane Gas). To decrease the pilot flame, turn the screw
clockwise (approximately six full turns to bottom of pilot
light channel) until you produce sufficient flame at the
minimum noise level.
PILOT
FLAME
ADJUSTMENT
Installation
of B-W Gas Vent
fol each subsequent
ceiling or
floor level ofmultistory
buildings¸
Firestop
spacels
supplied
manut'actm el of B-W
Ga s _n_
Plate
cut
away
of B-Yq Ga _ E_nt
Nail filestop
spacel
sect e y
FIGURE
C
NATURAL
GAS
SPECIFIC
ELEVATIONS
Model
0 to
2,000 -
4,000 -
&000 -
8.000 -
No.
2.000'
4.000'
6.000'
8.000'
10.000'
CF353C
34
36
37
38
41
CF357C
34
36
37
38
41
CF503C
3.4mm
31
31
32
35
CF557C
29
30
30
31
32
CF653C
26
27
28
29
30
ORDER KIT #49840 2287-1 HIGH ALTITUDE KIT
L.P. GAS
SPECIFIC
ELEVATIONS
Model
0 to
2,000 -
4,000 -
6,000 -
8.000 -
No.
2.000'
4,000'
6,000'
8,000'
10,000'
CF354C
50
52
52
53
54
CF358C
50
52
52
53
54
CF504C
45
47
48
49
50
CF558C 2.15mm
45
47
48
49
CF654C
42
43
44
45
47
ORDER KIT #49840 2287-1 HIGH ALTITUDE KIT
___. 3/8" TO 1/2"
STANDING PILOT
FIGURE 8-A
' TO
1/2"
I.I.D. PILOT
FIGURE 8-B
PILOT FLAME SHOULD ENVELOP 3/8 TO V_, I NCH
OF THE TIP OF THE GENERATOR.
Page 9