120 Volt AC, 30 Amp
Locking
Receptacle
Use a NEMA L5-30 plug with this receptacle. Connect a
3-wire cord set rated for 125Volts AC at 30 Amps to the
plug (Figure 8).
3-WireCord
Set
NEMA L5-30
_ Neutral
_d
(Green)
i
Use this receptacle to operate 120Volt AC, 60 Hz, single
phase loads requiring up to 3,600 watts (3.6 kW) of power
at 30 Amps.The outlet is protected by a push-to-reset
circuit breaker.
120 Volt AC, 20 Amp,
Duplex
Receptacles
Each duplex receptacle (Figure 9) is protected
against
overload by a push-to-reset
circuit breaker.
Use each receptacle to operate 120Volt AC, single-phase,
60 Hz electrical loadsrequiring up to 2,400 watts (2.4 kW)
at 20Amps of current. Use cord sets that are rated for
125Volt AC loads at 20 Amps (or greater).
COLD WEATH
ER
OPERATION
Under certain weather conditions (temperatures below
40°F [4°C] and a high dew point), your generator may
experience icingof the carburetor and/or the crankcase
breather system.
Build a structure that wilt enclose three sides and the top
of the generator:
I.
Make sure entire muffler-side of generator is exposed.
Note that your generator may appear different from
that shown in Figure 10.
2.
Ensure a minimum
of two
feet
clearance
between open
side of box and nearest object
3.
Face exposed end away from wind and elements.
4.
Enclosure should hold enough heat created by the
generator
to prevent problems.
DANGER
Operate
generator
ONLY outdoors.
Keep at least 2 feet of clearance
on all sides of generator
for
adequateventilation.
DO NOT operategenerator i nside any
building or enclosure,
including t he
generator compartment
of a recreational vehicle
(RV).
Removegeneratorfrom shelterwhen temperatureis above
40oF[4oc].