Basic serial command functional specifications
Hide thumbs Also See for PLC-WM5500/L - 5500 Lumens:
Table of Contents

Advertisement

PLC-WM5500/WM5500L Basic Serial Command Functional Specifications
7.8 Temp Read Command
Command
"CR6" [CR]
Get the information of temperature inside a projector.
Detail
With several built-in temperature sensors, it can get all the temperatures at once.
Acceptable
Response
Unacceptable
7.9 Lamp Mode Read Command
Command
"CR7" [CR]
Get lamp mode.
Detail
In the projector with single lamp, get ON/OFF status of the lamp
Acceptable
Response
Unacceptable
"%1 _ %2 _ %3" [CR]
%1 = Temp. of sensor 1
%2 = Temp. of sensor 2
%3 = Temp. of sensor 3
Temperature data basic format is "_00.0". ("_" indicates a space)
When the temperature goes under 0, it starts with "-" instead of a
%1
space like "-05.5" [CR].
%2
When no temperature data returns due to hardware problems, it
%3
starts with "E" like"E00.0" [CR].
With several built-in temperature sensors, the projector returns
the values in succession.
"_31.5_ _35.2_ 33.4 " [CR]
The first sensor's data is followed by one space and afterwards
the second sensor's data.
"?" [CR]
"%1" [CR]
%1
"00" [CR] = Lamp is ON.
"01" [CR] = Lamp is OFF.
"?" [CR]