Sanyo PLC-WM5500/L - 5500 Lumens Manual page 26

Basic serial command functional specifications
Hide thumbs Also See for PLC-WM5500/L - 5500 Lumens:
Table of Contents

Advertisement

PLC-WM5500/WM5500L Basic Serial Command Functional Specifications
"04" [CR]
Status: Power Save
This indicates it moves to Power-Save status by Power Management function as set in the
Setting menu.
"21" [CR]
Status: Cooling Down in process after OFF due to Lamp Failure
When the projector is turned off due to lamp failure, it automatically starts Cooling Down
operation. The projector returns "21" [CR]. "21" [CR] has been kept during Cooling Down
operation.
"81" [CR]
Status: Standby after Cooling Down due to Lamp Failure
The projector has recovered from Lamp Failure status. When the projector enters Standby
status after Cooling Down operation invoked due to lamp failure, it returns "81". This indicates
the status turns to Standby due to lamp failure. This status continues until the next operation
is started; when Power On is executed, the projector clears the information of Lamp Failure
and normal operation starts.
"2C" [CR]
Status: Cooling Down in process due to Shutter management function
This indicates it has moved to Cooling down status according to the setting of Shutter
Management function in setting menu. During this time, Functional Execution Commands are not
accepted.
"8C" [CR]
Status: Standby after Cooling Down due to Shutter management function.
This value is returned when Cooling Down operation due to Shutter management has been
completed and the status has been moved to Standby. The status is kept until the next operation
starts. When projector is turned on again, it cancels the last status and starts normal operation.
26/28

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-wm5500/lPlc-wm5500

Table of Contents