PILOT LIGHT TROUBLESHOOTING
CHART
Section A: Pilot light will not light (new installation).
Section C: Pilot light will not remain lit.
Check for insufficient combustion
air. m
Is the manual gas shut-off valve,
/
•lTurn
the manual gas shut-off valve to
I
located in the supply line to the
IN NO _lthe
on position and follow the lighting
I
m water heater, inthe°np°siti°n?/
" minstructi°ns °n the fr°nt °f the water heater" m
YES
/
• IWhile repeatedly depressing
the igniter
Have you bled all the air
from the pilot tube and
IN NO_lbutton,
push in and hold the gas control/
[gas supp y ne?
|
--Itemperature
knob until the pilot is lit and
a
maintains
a stable flame, (status light
YES
will blink) then release the gas control/
temperature
knob.
Is S 0nte' r° ucin0a !
Follow the "Testing the Igniter
System sect on n th s manual.
I
lSet thermostat
to desired temperature"
J
Section B: Pilot light repeatedly goes out.
Remove the burner door
Refer to the "Maintenance
of
/
assembly. Are the flame-trap and
ik Iyour Water Heater" section of this L
==NO
.
.
.
burner free from debris due to
lip
manual for informatlon on cleanlng |
excessive lint, dirt, dust or oil?
the flame-trap and burner.
I
II
YES
/
,!, 4,
Does the flame-trap IN
Reassemble
the heater, press the thermal I
show signs of
NON_,
switch, and attempt to return the heater to
/
d sco orat on?
serv ce. Does the p ot rema n t?
YES
YES
NO
m
Shut-off the gas supply to the water heater at the
I /
manual gas shut-off valve, use the number on the
I
!
cover of th s manua to contact Customer Serv ce.
ISet to desired temperature.
I
Does the diagnostic status light on the
gas control valve/thermostat give
a two fash error code?
YES
Go to section C. I
",I,
Refer to the "Replacing the Pilot
I
Assemby
nstructons
n the manua.
I
!
I Reassemble
and restore to service. I
Are the combustion
air supply and ventilation openings
• ICorrect size of
of sufficient size? See "Combustion Air Supply and
m NOmlpIopenings
to allow
Ventilation" section in this manual for requirements.
|surf
cent a r.
Y_S
÷
mNOmlls there a furnace/air
handler in the same room as the water heater? I
YES
Does the return air duct for the furnace/
air handler draw its air from a separate
IContact a local Heating,
I
location than the water heater? See the
• IVentilation,
Air-Conditioning
I
"Location Requirements"
section and
NNO_
1& Refrigeration
authorized
I
the "Combustion Air Supply" section.
I
service pr°vider t° c°rrect
I
lthe
combustion
air supply/
I
YES
|
ventilation
issue.
I
÷
ls there proper drafting at the |
ICheck the vent
Idrafthood?
See "Checking thelm NO mll_system
for restrictions/
Draft'' section in this manual.
Y Iobstructions and check
Y[=S
|the
vent termination
II
|height.
Refer to the
II
|"installation
Instructions"
II
|section
of this manual for
/
specific requirements.
Reference
the number
on the cover of this
I
lmanua
for serv ce nformat on.
J
NOTE:
If you are still experiencing
difficulties
after
following
the steps in sections A, B, and C, use the
number on the cover of this manual to contact Customer
Service.