Operating The Temperature Control System - American Water Heater AMERICAN WATERHEATERS Installation And Use Manual

Residential gas water heater with the flame guard safety system
Table of Contents

Advertisement

Operating the Temperature Control System
LOW
C
Status Light Code
Normal Flashes:
0 Flashes
Indicates Control Off/Pilot Out.
1 Flash Indicates Normal Operation.
Continuous Light indicates the gas control
valve/thermostat
is shutting down.
Diagnostic Flashes: If the water heater is not working look
for the following diagnostic flashes after lighting the pilot.
Figure 19B: Status Codes
List of status codes are shown
at top of gas control valve/thermostat.
2 Flashes
4 Flashes
5 Flashes
7 Flashes
8 Flashes
Indicates Thermopile Voltage Low
Indicates Overheat Failure
Indicates Sensor Failure
Indicates Electronic Control Failure
See "Status Light Code Troubleshooting Chart."
Water Temperature Adjustment
The water temperature can be adjusted from 55°F to 155°F.
Turn the Gas Control/Temperature
Knob to the desired
setting/temperature.
NOTE: Some models are certified for 180°F outlet
temperatures.
See the Data Plate on the front of the water
heater for the maximum outlet temperature.
Operating
Modes and Settings
Standard
Mode - The controller adjusts the water
heater to maintain the temperature set by the user.
Vacation Setting - The controller adjusts the water
temperature to approximately 55°F. This setting is
recommended when the water heater is not in use for
a long period of time. This effectively turns the water
heater down to a setting that prevents the water from
freezing.