Amana AAC081SRA Service Manual page 26

Slide out chassis room air conditioner
Hide thumbs Also See for AAC081SRA Service:
Table of Contents

Advertisement

--
_k
WARNING
HiGH TEMPERATURE
STRESS
HAZARD
This room
air conditioner
is not meant
to
provide unattended
cooling or life support
for persons
or animals
that are unable
to
react to failure
of the product.
The failure
of an unattended
air conditioner
may result in extreme heat in the conditioned
space
causing
overheating
or death
of
persons or animals.
Precautions
must be taken
to ward off or
guard against such an occurrence.
II. Unpacking
When unpacking
visually inspect the unit.
Report any
damage to the delivering carrier immediately.
Remove and
discard all packing material.
On some models the air
conditioner
front and/or mounting kit hardware may be
packed separately.
Record the model, serial and manufacturing
numbers of
your unit in the space provided below. This information is
found on a nameplate visible on the right hand side of the air
conditioner outer case. The rated voltage, amperage and
capacity for your specific model can also be found on this
nameplate.
Read the warranty provided on the last page of
this manual. Keep this manual and a copy of your sales
receipt for future reference.
You may also want to record in
the space provided the date purchased and the selling
dealer.
OWNER'S
PRODUCT
IDENTIFICATION
MODEL
NUMBER
SERIAL
NUMBER
MANUFACTURING
NUMBER
Owner's Name
Address
City
State
Zip
/
/
Date of Purchase
Authorized
Dealer
Address
City
State
Zip
(
/
Phone Number
III. Electrical
Requirements
ELECTRICAL
GROUNDING INSTRUCTIONS
This appliance is equipped with a three-prong
grounding
plug for protection against possible shock hazards
Ifa two-
prong wall receptacle is encountered, the customer is re-
quired to contact a qualified electrician and have the two-
prong wall receptacle replaced with a properly grounded
three-prong wall receptacle in accordance with the National
Electrical Code.
Room air conditioners are designed to operate according to
requirements
on the nameplate and as shown in Table 1
Fuse or circuit breaker ratings must be according to the fuse
instruction label and as shown in Table 1 and the label on the
electrical cord Do not plug models marked
"Use on Single Outlet Circuit Only"
into a circuit with another appliance or light fixture.
_k
WARNING
To avoid death, personal injury or property
damage
due to electrical
shock,
this unit
must
be grounded.
Do not
under
any
circumstances
cut
or remove
the round
grounding
prong from the plug. Do not use
a two-prong
adapter.
WARNING
To avoid death, personal injury or property
damage
due to electrical
shock,
do not use
an extension
cord. Do not pinch the power
cord.
Do not remove
the warning
tag from
the power cord.
Circuit Rating
Unit Plug Type
Receptacle
Breaker or
Voltage Rating
required
Time
On Unit Nameplate
Delay Fuse
(_
_
125V-15AMP
115V
NEMA No 5-15F
NEMA No 5-15R
(_
_
230/208V
rated
250V-15AMP
at 12 amperes or less
NEMA No. 6-15F
NEMA No. 6-15R
{_
_
230/208V
rated over
250V-20AMP
12 amperes but not mor_
than 16 amperes
kIEMA No 6-20F
NEMA No. 6-20R
_
230/208V
rated
250V-30AMP
at 24 amperes or less
NEMA No. 6-30F
NEMA No 6-30R
Table 1
@2003
MaytagAppliancesCompany
16022061
Rev. 0
A-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aac121sraAac101sraAac141sraAac182sraAac202sraAac242sra

Table of Contents