Trouble
Shooting
OPERATION_
(continued)
TOPIC
POSSIBLE
CAUSE
SOLUTION
Refrigerator runs too
Controls need to be adjusted.
frequently (continued)
Door is not closing properly.
ICE
See controls section in your Owner's Manual for assistance
in how to adjust your controls.
Refrigerator is not level, See How to Level Your
Re#igeratorfor
details on how to level your unit.
Check gaskets for proper seal. Clean, if necessary,
according to cleaning instructions in owner's manual.
Check for internal obstructions that are keeping door from
closing propedy (i.e. impropedy closed drawers, ice
buckets, oversized or improperly stored containers or
, foodstuffs, etc.).
Unit is leaking
water
Ice forms in inlet tube to ice
maker
Water flow is slower than
normal
Plastic tubing was used to complete water
connection.
Improper water valve was installed.
Amana recommends using copper tubing for installation.
Plastic is less durable and can cause leakage. Amana Is
not responsible for property damage due to improper
installaUon or water connection.
Check water connection
procedure
in your Installation
Instructions.
Self-piercing
and 3/1s"saddle
valves cause
low
water pressure
and may clog the line over time, Amana
is
not responsible
for property
damage
due to improper
installation
or water
connection.
Water pressure is low.
Water pressure must be between 20 to 100 pounds per
square inch to function propedy. A minimum pressure of 35
pounds per square inch is recommended for units with
water filters.
Freezer temperature is too high.
See the controls section in your owner's manual for
assistance on how to adjust your controls. Freezer is
recommended to be between 0 to 2=F (-18 to -17°C).
Water pressure is low.
Water pressure must be between 20 to 100 pounds per
square inch to function propedy. A minimum pressure of 35
pounds per square inch is recommended for units with
water filters.
Improper water valve was installed.
Check water connection procedure in your Installation
Instructions. Self-piercing and
3/16"
saddle valves cause low
water pressure and may clog the line over time, Amana is
not responsible for property damage due to Improper
installation or water connection,