DETERMINE
VENT
LENGTH
Maximum Exhaust Lengths:
• Rear Exhaust. The maximum length
of the rear exhaust system depends
on the type of vent, the number of
elbows and the type of exhaust hood.
Refer to the chart below.
• Side Exhaust. Side exhaust adds
a 90 ° turn inside the laundry center.
To determine
maximum exhaust
length, add one 90 ° turn to the chart.
EXHAUST HOOD TYPE
Number of
Maximum length of 4-inch
90 ° Turns diameter rigid heavy metal vent.
0
36 ft.
34 ft.
29 ft.
1
26 ft.
24 ft.
20 ft.
2
16ft.
14ft.
12ft.
Number of
Maximum length of 4-inch
90° Turns diameter flexible heavy metal vent.
0
22 ft.
21 ft.
16 ft.
1
16ft.
15ft.
10ft.
2
8ft.
7ft.
2ft.