Secure to Collars with
Duct Tape or Screws
Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)
Figure 12 - Outside Air Kit Installation
ChIMNEY PIPE
The DESA Heating, LLC chimney system is
a snap-lock, double-wall pipe. It consists of a
stainless steel inner flue pipe(s), a galvanized
outer pipe and a wire spacer. Each section of
pipe comes in lengths of 12", 18", 36" and 48".
The actual lineal gain for each is measured
after each section is fully connected. Lineal
gain is the actual measurable length of a part
after two or more parts are connected.

PIPE INSTALLATION

The pipe sections must be assembled indepen-
dently as the chimney is installed. When connect-
ing chimney directly to the firebox, the inner flue
LINEAL GAIN
PART NO.
DESCRIPTION
368STM
See-Through
V368ST
See-Through
(V)12-8DM
(V)18-8DM
(V)24-8DM
(V)36-8DM
(V)48-8DM
VRTL-8DM
Termination
VRTTL-8DM
VETL-8M
VETO-8DM
Termination
VETLO-8DM
55511E
VenTing inSTALLATion
Air Inlet
Location
Must Allow
For Bushes
or Snow
Air Inlet
Termination
Vent Hood
Required for
Wall Installation
GAIN
66
Flue Pipe
10
Flue Pipe
16
Flue Pipe
23
Flue Pipe
34
Flue Pipe
46
Round Top
Econo-Top
1" to 12"
www.desatech.com
Continued
pipe section must be installed first with the lanced
side up. The outer pipe section can then be in-
stalled over the flue pipe section with the hemmed
end up. Press down on each pipe section until the
lances securely engage the hem on the firebox
starter. The wire will assure the proper spacing
between the inner and outer pipe sections.
Continue to assemble chimney sections as
outlined above, making sure that both the inner
and outer pipe sections are locked together
(see Figure 13). When installing double wall
snap-lock chimney together, it is important to
assure the joint between the chimney sections
is locked. Check by pulling chimney upward
after locking. The chimney will not come apart
if properly locked. It is not necessary to add
screws to keep the chimney together.
FIRESTOP SPACERS VFS-8DM
(24 PACK)
Firestop spacers are required at each point
WARNING: The opening in the
collar around the chimney at the top
of the firebox must not be obstruct-
ed. Never use blown insulation to
fill the chimney enclosure.
12
/
" Galvanized
3
8
Outer Pipe
8" Stainless
Inner Pipe
Lanced Side
Up
Figure 13 - Pipe Connection
where the chimney penetrates a floor or ceil-
ing joist space. Their purpose is to establish
/
"
1
4
and maintain the required clearance between
54"
the chimney and the combustible materials.
/
"
When penetrating a floor or ceiling at an angle,
5
8
use firestop spacer number V30FS-8DM (see
/
"
5
8
Replacement and Accessory Parts, page 14).
/
"
5
When the pipe passes through a framed open-
8
ing into a living space above, the firestop must
/
"
5
8
be placed onto the ceiling from below as shown
/
"
5
8
in Figure 14, page 8. When the pipe passes
through a framed opening into an attic space
6"
above, the firestop must be placed on the attic
floor as shown in Figure 15, page 8.
SUPPORT SECTIONS
The chimney support section is a 4" strap